| 2008-01-03 17:31:52 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY |
| | |
| | _XX_1.)EFFECTIVE OCTOBER 1, 2007, SECONDARY WATER |
| | BARRIER REQUIRED FS553.844(5)(A). PROVIDE |
| | INFORMATION (PRODUCT APPROVAL OR SPECIFICATIONS) TO |
| | SHOW HOW YOU WILL COMPLY WITH THIS REQUIREMENT. |
| | INFORMATION IS AVAILABLE AT WWW.BOAF.NET, HURRICANE |
| | MITIGATION.PROVIDE DETAILED INFORMATION FOR BOTH THE |
| | PITCH ROOF. |
| | |
| | PLEASE DESCRIBE THE SYSTEMS YOU ARE USING, FOR THE |
| | SINGLES AND FOR THE FLAT DECK.METHOD OF COMPLIANCE |
| | WITH FS553.844(5)(A), SECONDARY WATER BARRIER, TO BE |
| | SPECIFIED FOR EACH SYSTEM. |
| | |
| | _XX_4.)FOR THE LOW SLOPE ROOF, SELECT THE APPROVED |
| | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER |
| | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE |
| | LIMITATIONS. |
| | |
| | MULEHIDE TILE UNDERLAYMENT, TAMKO UNDERLAYMENT WERE |
| | SUBMITTED.WHICH ARE YOU USING?YOU'VE CIRCLED TILE |
| | UNDERLAYMENT SYSTEM FOR MULEHIDE.TAMKO TW IS ALSO A |
| | TILE UNDERLAYMENT. |
| | |
| | THE ASSEMBLY SELECTED IS FOR TILE UNDERLAYMENT.SELECT |
| | AN ASSEMBLY FOR THE FLAT DECK. |
| | |
| | _XX_5.)FOR THE LOW SLOPE ROOF, SPECIFY THE ENHANCED |
| | FASTENING FOR CORNER AND PERIMETER ZONES.THIS IS TO |
| | BE EITHER WRITTEN ON THE PRODUCT APPROVAL OR SUBMITTED |
| | ON LETTERHEAD, TWO SETS (NOT WRITTEN ON THE RESUB |
| | SHEET). |
| | |
| | _XX_ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS |
| | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF |
| | CONSULTANT REQUIRED FOR ENHANCED FASTENING. |
| | |
| | DOCUMENTS PREPARE BY AN ENGINEER AND SUBMITTED FOR |
| | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS |
| | UNLESS EXEMPTED BY FLORIDA STATUTE.YOU'VE SUBMITTED |
| | POLYGLASS ENGINEERING, BUT ARE NOT USING THE POLYGLASS |
| | PRODUCT.THE ENGINEERING IS TO BE ORIGINAL UNLESS |
| | EXEMPTED. |