| 2008-01-04 10:36:05 | J. B. HGANOVER & CO. |
| | JAN. 04, 2008 |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07120585 |
| | ADD: 525 OKEECHOBEE BLVD. SUITE 700 |
| | CONT: PASS INTERNATIONAL |
| | TEL: (954)421-9000 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS * WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS, |
| | REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR |
| | REVIEW FOR PERMIT. |
| | IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF |
| | YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A |
| | THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID |
| | DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1* |
| | /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH |
| | ADMINISTRATIVE CODE. |
| | |
| | 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 |
| | DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN |
| | THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF |
| | MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY |
| | WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE |
| | SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS |
| | A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS |
| | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS |
| | DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE2007 SUPPLEMENTS. SHEET A-0.1.1 |
| | PLEASE UPDATE APPLICABLE CODES TO THE CURRENT |
| | 2007 FBC SUPPLEMENTS. |
| | |
| | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) THE SHELL BUILDING HAS NOT ACHIEVED A CERTIFICATE OF |
| | COMPLETION, THE CONTRACTOR FOR THIS TENANT SPACE IS |
| | DIFFERENT FROM THE "BASE BUILDING" AND WILL REQUIRE A |
| | LETTER FROM THE BASE BUILDING CONTRACTOR ALLOWING PASS |
| | INTERNATIONAL TO START WORK ON THIS TENANT SPACE BEFORE |
| | THE CERTIFICATE OF COMPLETION FOR THE BASE BUILDING HAS |
| | BEEN ISSUED. THE DEVELOPER AND BOTH G.C.'S WILL HAVE TO |
| | SUBMIT A LETTER STATING THAT THEY UNDERSTAND THAT ANY |
| | DISPUTE OVER RESPONSIBILITY DOES NOT RELIEVE THEM FROM |
| | THE JOINT RESPONSIBILITY TO COMPLY WITH THE BUILDING |
| | CODE. |
| | . 106.1.2 ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 5)PLEASE SEE DISCREPANCY BETWEEN THE SUITE NUMBER ON |
| | THE PERMIT APLICATION AND SHEET A-1.7.1. 106.1.2 |
| | ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 6)SHEET A-3.7.1 PLEASE SEE DETAIL NUMBER (3) THE |
| | RECEPTION DESK INDICATES A GRANITE STONE TRANSACTION |
| | TOP WITH S S POST AT A HEIGTH OF 3'-6", PLEASE PROVIDE |
| | COMPLIANCE WITH 11-7.2 SERVICE COUNTERS. |
| | |
| | 7) SHEET A-6.7.1 & A-6.7.2 BOTH INDICATE VARIOUS WALL |
| | DETAILS WHERE 2X4 WOOD BACKING WILL BE REQUIRED, PLANS |
| | DO NOT INDICATE THAT IN TYPE I & TYPE II BUILDING NO |
| | COMBUSTIBLE ALLOWED IN WALLS WITH THE EXCEPTION OF FIRE |
| | RETARDANT TREATED WOOD, SEE 603.1(1). |
| | |
| | 8) SHEET A-7.7.1 DOOR SHCEDULE UNDER THE DOOR RATING |
| | COLUMN INDICATE FIRE RATED DOORS AS "C" LABEL, PLEASE |
| | SEE TABLE 715.3 RATES DOORS IN MINUTES AND HOURS. |
| | |
| | |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | |
| | |
| | |
| | |