| Date |
Text |
| 2008-02-06 16:47:08 | BUILDING PLAN REVIEW |
| | PERMIT: 07120459 |
| | ADD: 8989 OKEECHOBEE BLVD #212 |
| | CONT: CHOEN INC. |
| | TEL: (561)362-4217 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 3RD |
| | ACTION: DENIED |
| | 2/06/08 |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | **NO RESPONSE NOT ADDRESSED** |
| | 1B)) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 1C) OK |
| | 2)OK |
| | 3)OK |
| | 4)OK |
| | 5)OK |
| | 6)OK |
| | |
| | **NEW** |
| | **NO RESPONSE NOT ADDRESSED** |
| | A) THE NEW DRINKING FOUNTAIN LOCATION WILL HAVE TO |
| | COMPLY WITH FBC 1016.2 (EXCEPTIONS) #2. THE CORRIDOR |
| | WIDTH SHALL BE 36 INCHES WHEN THE OCCUPANT LOAD IS 50 |
| | OR LESS. THE INSTALLATION OF THE DRINKING FOUNTAIN AT |
| | THIS LOCATION WILL PROHIBIT A PERSON IN A WHEELCHAIR |
| | ACCESS TO THE BATHROOM. THE SPACE INDICATED ON THE |
| | DRAWINGS IS 30 INCHES. SHEET A2 SHOWS FOUR DIFFERENT |
| | TYPES OF DRINKING FOUNTAINS; CIRCLE THE ONE WHICH WILL |
| | BE INSTALLED. |
| | |
| | FBC1008.1.1.1. THERE SHALL NOT BE PROJECTIONS INTO THE |
| | REQUIRED CLEAR WIDTH LOWER THAN 34 INCHES (864 MM) |
| | ABOVE THE FLOOR OR GROUND. PROJECTIONS INTO THE CLEAR |
| | OPENING WIDTH BETWEEN 34 INCHES (864 MM) AND 80 INCHES |
| | (2032 MM) ABOVE THE FLOOR OR GROUND SHALL NOT EXCEED 4 |
| | INCHES (102 MM) |
| | |
| | FBC11-4.4.1 |
| | OBJECTS PROJECTING FROM WALLS (FOR EXAMPLE, TELEPHONES) |
| | WITH THEIR LEADING EDGES BETWEEN 27 INCHES AND 80 |
| | INCHES (685 MM AND 2030 MM) ABOVE THE FINISHED FLOOR |
| | SHALL PROTRUDE NO MORE THAN 4 INCHES (102 MM) INTO |
| | WALKS, HALLS, CORRIDORS, PASSAGEWAYS, OR AISLES [SEE |
| | FIGURE 8 (A)]. OBJECTS MOUNTED WITH THEIR LEADING EDGES |
| | AT OR BELOW 27 INCHES (685 MM) ABOVE THE FINISHED FLOOR |
| | MAY PROTRUDE ANY AMOUNT [SEE FIGURE 8 (A) AND FIGURE 8 |
| | (B)]. FREE-STANDING OBJECTS MOUNTED ON POSTS OR PYLONS |
| | MAY OVERHANG 12 IN (305 MM) MAXIMUM FROM 27 INCHES TO |
| | 80 INCHES (685 MM TO 2030 MM) ABOVE THE GROUND OR |
| | FINISHED FLOOR [SEE FIGURE 8 (C) AND FIGURE 8 (D)]. |
| | PROTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH OF |
| | AN ACCESSIBLE ROUTE OR MANEUVERING SPACE [SEE FIGURE 8 |
| | (E)]. |
| | |
| | B)61G1-16.004. THE TITLE BLOCK ON THE DRAWINGS SHALL |
| | INCLUDE. |
| | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. |
| | (2) FIRM LICENSE NUMBER. |
| | (3) NAME OR IDENTIFICATION OF PROJECT. OK |
| | (4) DATE PREPARED. |
| | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. |
| | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING |
| | THE DOCUMENT.OK |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |