| 2008-02-28 17:08:37 | |
| | |
| | DENIED |
| | |
| | THE FOLLOWING COMMENTS FROM THE 1ST REVIEW WERE NOT |
| | ADDRESSED |
| | |
| | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | *******NOTE: FEES ARE DUE IN THE AMOUNT OF $226.63 FOR |
| | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN |
| | REVIEW******** |
| | |
| | 5)PROVIDE 2 COPIES OF A RECENT SURVEY/SITE PLAN |
| | SHOWING THE PROPOSED BUILDING/ADDITION WITH ALL |
| | SETBACKS. *******AREA OF CONCERN IS NEW FRAMED WALL |
| | THAT IS INSTALLED IN LINE WITH EXISTING WALL THAT |
| | ENCROACHES INTO 25 FOOT MIN FRONT SETBACK********* |
| | |
| | 11)NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOF DECK |
| | ABOVE STUDY AND ON BALCONY,NEW DOOR UNIT WITH GLAZED |
| | SIDELITES AND CONNECTORS AND STRAPS. IN LUE OF PRODUCT |
| | APPROVALS STRAPS/CONNECTORS MAY BE LISTED IN A SCHEDULE |
| | ON THE DRAWINGS COMPLETE WITH THE STATEWIDE PRODUCT |
| | APPROVAL NUMBERS OR SUBMIT SIMPSON TIE'S COMPLETE |
| | FLORIDA INDEX WITH CONNECTORS TO BE USED HIGHLIGHTED. |
| | |
| | 19)PROVIDE A KEY PLAN (WITH EGRESS SHOWN), SHUTTER |
| | SCHEDULE AND THE PRODUCT APPROVALS. APPROVAL DRAWINGS |
| | SHALL BE MARKED FOR MOUNTING METHOD AND CONNECTION TYPE |
| | AND THE SCHEDULE FILLED OUT WITH ALL PERTINENT |
| | INFORMATION SPECIFIC TO THE SITE (TYPE OF CONSTRUCTION, |
| | MOUNTING CONNECTION METHOD, ANCHOR TYPE, SHUTTER SPAN |
| | (VERTICAL OR HORIZONTAL), ETC.) PLEASE SEE THE ATTACHED |
| | MEMO AND SCHEDULE. |
| | |
| | NEW COMMENTS |
| | |
| | 1)THE FLORIDA PRODUCT APPROVAL FOR THE NEW FRONT |
| | ENTRY DOOR WAS NOT SUBMITTED WITH THE CORRECT |
| | COMPLIANCE REPORT, IF THIS IS THE DOOR TO BE INSTALL |
| | PROVIDE THE "ARCHITECTURAL TESTING INC," REPORT THAT IS |
| | FOUND UNDER THE LINK. IF THE MODEL YOU HAVE CHOSEN IS |
| | NOT COVERED BY THE STATE AND IT IS THE ONE IN THE |
| | MIAMI-DADE REPORT,A LOCAL PRODUCT APPROVAL WILL BE |
| | GRANTED ON THE MIAMI-DADE NOA/COMPLIANCE REPORT. |
| | |
| | 2)PLEASE REMOVE THE CYPRESS ENTRY DOOR FRAME DETAIL |
| | FROM THE DRAWINGS AND PROVIDE FRAMED WALL DETAILS FOR |
| | NEW ENTRY DOOR |
| | |
| | 3)PLEASE NOTE THAT ONE SET OF DRAWINGS IS MISSING THE |
| | ARCHITECTS SIGNATURE ON SHEET A-2 |
| | |
| | 4)PLANS THAT ARE REVISED AND NEW PAGES SHALL BE |
| | REVIEWED AND APPROVED BY THE HISTORIC PRESERVATION |
| | DIVISION |
| | |
| | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 |
| | AMENDMENTS |
| | FBC* = WEST PALM BEACH ADMINISTRATIVE |
| | AMENDMENTS TO FBC |
| | FAC = FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | FBC RES. = FLORIDA BUILDING CODE |
| | RESIDENTIAL 2004 W/2006 AMENDMENTS |
| | |
| | ******ADDITIONAL PERMITS WILL BE REQUIRED FOR PLUMBING, |
| | ELECTRICALAND ROOFING****** |
| | |
| | REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF |
| | NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF THE |
| | OLD PAGES ONLY FOR REFERENCE. |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |