| 2008-02-07 08:07:23 | ****************PROVISO**************** | | | A} PER FBC PLUMBING, SECTION 704.5 | | | DEAD ENDS: IN THE INSTALLATION OR | | | REMOVAL OF ANY PART OF A DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | | A PLUMBING PERMIT IS REQUIRED AND AN | | | INSPECTION IS REQUIRED OF DEMO WORK PRIOR | | | TO COVERING DEMO WORK WITH FINNISH | | | WALLS, CIELINGS, OR POURED CONCRETE | | | SLABS. | | | | | | B} PER FBC PLUMBING SECTION *802.2 DISHWASHING | | | MACHINES SHALL DISCHARGE INTO A WYE-BRANCH FITTING ON | | | THE TAILPIECE OF THE KITCHEN SINK. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] | | | |
|