| 2008-03-01 08:29:44 | |
| | |
| | DENIED |
| | |
| | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM THE 1ST |
| | REVIEW: |
| | |
| | |
| | |
| | 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | |
| | NOTE: FEES ARE DUE IN THE AMOUNT OF $208.69 FOR |
| | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW |
| | |
| | 6)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT |
| | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR |
| | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND |
| | APPROVED BY THE DESIGNER OF RECORD. *******THE DRAWINGS |
| | SUBMITTED ARE NOT SIGNED AND SEALED BY THE TRUSS |
| | MANUFACTURERS ENGINEER, PLEASE HAVE ENGINEERED SETS |
| | THAT ARE REVIEWED AND APPROVED BY YOUR DESIGNER OF |
| | RECORD AVAILABLE TO INSPECTOR PRIOR TO TRUSS |
| | ERECTION******** |
| | |
| | 7)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER |
| | R803.2.3.1 FBC RES. 4" EDGES AND 6' FIELD IN ZONES 1 & |
| | 2 AND 4" EDGES AND FIELD IN ZONE 3 ****** PLEASE NOTE |
| | THAT SHEETS 2 AND A HAVE CONFLICTING INFORMATION ALSO |
| | ZONE 3 REQUIRES 4" O/C AT EDGES AND FIELD IN 140 MPH |
| | WIND ZONE****** |
| | |
| | 10)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE |
| | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. |
| | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG ******NO |
| | PRODUCT APPROVALS WERE SUBMITTED FOR MULLIONS, AND |
| | CONNECTORS AND STRAPS. IN LUE OF PRODUCT APPROVALS |
| | STRAPS/CONNECTORS MAY BE LISTED IN A SCHEDULE ON THE |
| | DRAWINGS COMPLETE WITH THE STATEWIDE PRODUCT APPROVAL |
| | NUMBERS OR SUBMIT SIMPSON TIE'S COMPLETE FLORIDA INDEX |
| | WITH CONNECTORS TO BE USED HIGHLIGHTED****** |
| | |
| | 12)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| | STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. |
| | THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. |
| | WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE |
| | DENIED |
| | ******NOT SUPPLIED FOR THE PGT DOORS, PGT WINDOWS, |
| | METAL TECH STORM PANELS,CASTCRETE LINTELS PLESE SEE |
| | TOP OF NOA'S FOR FLORIDA STATEWIDE PRODUCT APPROVAL |
| | NUMBERS. SEE ROOFING PRODUT APPROVALS FOR EXAMPLE OF |
| | THESE SHEETS********* |
| | |
| | 13)PRODUCT APPROVALS WERE SUBMITTEDEASTERN METAL |
| | SUPPLY,CIRCLE THE METHOD THAT WILL BE USED TO MOUNT |
| | THE PANELS AND FILL OUT A SHUTTER SCHEDULE WITH KEY |
| | PLAN FOR THE OPENINGS PER WEST PALM BEACH MEMO (SEE |
| | ATTACHED) *******INFORMATION AND SCHEDULE WERE INSERTED |
| | WITH FIRST REVIEW COMMENTS, PRODUCT APPROVALS WERE NOT |
| | MARKED WITH INSTALLATION METHOD AND NO INSTALLATION |
| | SCHEDULE HAS BEEN PROVIDED******** |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |