| Date |
Text |
| 2007-12-19 11:40:56 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| | (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| | |
| | PLUMBING PLAN REVIEW: |
| | DENIED: |
| | |
| | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. |
| | |
| | 1. PERMIT APPLICATION STATES RENOVATION AND REPAIR |
| | PLUMBING, HOWEVER THE SUBMITTED PLANS ON SHEET 1 (BOTH |
| | SETS 1017, 1017 1/2 AND 1019, 1019 1/2) ARE INDICATING |
| | THE FOLLOWING "NOTE, PLUMBING EXISTING" WITH A |
| | ISOMETRIC SANITARY RISER DIAGRAM THAT DOES NOT REFLECT |
| | THE FLOOR PLAN OR IS CODE COMPLIANT. PLEASE REFERENCE |
| | THE CORRECTED SANITARY ISOMETRIC RISER DIAGRAM THAT |
| | REFLECTS THE FLOOR PLAN AND IS CODE COMPLIANT. CLEARLY |
| | INDICATE ON THE RESUBMITTED PLANS WHAT PLUMBING WORK IS |
| | GOING TO BE DONE. PER *106.1.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS AND *106.1.2 ADDITIONAL DATA. |
| | |
| | 2. SHEET 1, ISOMETRIC SANITARY RISER DIAGRAM:PER |
| | FBC-2004 CHAPTER 1, SECTION 106.3.5.4 RESIDENTIAL (ONE |
| | AND TWO-FAMILY)(9) PLUMBING: PLEASE SUBMIT A PLUMBING |
| | SANITARY ISOMETRIC RISER DIAGRAM INDICATING ALL WASTE, |
| | VENTS, TRAPS AND SIZES WITH CLEANOUT LOCATIONS.**THE |
| | SUBMITEED RISER DIAGRAM ALSO DOES NOT COMPLY WITH THE |
| | FOLLOWING AS WELL AS WHAT WAS STATED IN COMMENT 1. |
| | |
| | (A) 406.3 WASTE CONNECTIONS.THE TRAP AND |
| | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES |
| | WASHER SHALL BE A MINIMUM OF 2 INCHES |
| | (51MM) IN DIAMETER. THE AUTOMATIC |
| | CLOTHES WASHER FIXTURE DRAIN SHALL |
| | CONNECT TO A BRANCH DRAIN OR DRAINAGE |
| | STACK A MINIMUM OF 3 INCHES (76MM) IN |
| | DIAMETER. |
| | (B) 708.3.4 BASE OF STACK. A CLEANOUT |
| | SHALL BE PROVIDED AT THE BASE OF EACH |
| | WASTE OR SOIL STACK |
| | (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL |
| | BE THE SAME NOMINAL SIZE AS THE PIPE |
| | THEY SERVE UP TO 4 INCHES (102MM) |
| | **CLEANOUT FOR THE WASHING MACHINE SHALL BE 3". |
| | (D) 708.9 ACCESS. ACCESS SHALL BE |
| | PROVIDED TO ALL CLEANOUTS. |
| | **CLEANOUT FOR THE WASHING MACHINE SHALL BE LOCATED 4' |
| | A.F.F. |
| | |
| | 3. FBC-2004 CHAPTER 1,SECTION 106.3.4.3: |
| | THE PERSON RESPONSIBLE FOR THE DESIGN OF |
| | THE DRAWING SHALL CLEARLY PRINT AND SIGN |
| | NAME, AND ALSO DATE DRAWING. |
| | PLEASE DO THIS PRIOR TO RESUBMITTING. |
| | |
| | ********IMPORTANT INFORMATION******** |
| | WHEN RESUBMITTING PLANS, PLEASE INDICATE THE REVISION |
| | AND REMOVE & REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | NOTE: THERE IS ONLY ONE CORRECTED DRAWING |
| | IN RED INK ON THE INDICATED PLAN SHEETS BY THIS PLANS |
| | EXAMINER FOR REFERENCE FOR THE |
| | RESUBMITTAL. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY: MIKE PERSON |
| | PLUMBING PLANS EXAMINER |
| | PHONE= (561) 805-6730 |
| | FAX= (561) 805-6731 |