| Notes |
| Date |
Text |
| 2008-07-14 08:25:18 | REVISION: "OK" NEW LONGEST LENGTH OF 300'. (SEE RED | | | LINE CHANGES TO CSST IN ATTIC) | | | | | | ****************PROVISO**************** | | | IF WATER HEATER ROOM IS A CONFINED | | | SPACE, OPENINGS REQUIRED PER SECTION | | | 304.5 OR SECTION 304.6 SHALL BE | | | INSTALLED. | | | MINIMUM 3,750 CUBIC FEET REQUIRED. | | | | | | FUTURE GENERATOR GAS PIPING AT OWN RISK, SEPERATE | | | GEN/RES PERMIT REQUIRED WITH ZONING APPROVAL OF | | | GENERATOR PLACEMENT. | | | NOTE: PER FBC-2004 FUEL GAS SECTION, 404.12 OUTLET | | | CLOSURES. GAS OUTLETS THAT DO NOT CONNECT TO APPLIANCES | | | SHALL BE CAPPED GAS TIGHT. IF GAS DELIVERY PRESSURE IS | | | 2 PSI OR GREATER MP REGULATORS SHALL BE INSTALLED PRIOR | | | TO FINAL INSPECTION. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|