| 2007-11-06 17:43:12 | PROJECT: 3920 NORTH FLAGLER DRIVE/07110090 |
| | |
| | PROJECT DETAIL: MARBLE FLOORING INSTALLATION |
| | |
| | PLAN REVIEW: |
| | |
| | 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS |
| | 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS |
| | CITY OF WEST PALM BEACH/ FLORIDA BUILDING CODE, |
| | ADMINISTRATION AMENDMENTS, CHAPTER 1, 2004 EDITION |
| | |
| | STATUS: FAILED |
| | |
| | COMMENTS: |
| | |
| | 1) PLEASE PROVIDE (2) COPIES OF THE ENGINEERING LETTER |
| | REFERENCING THE TILE INSTALLATION. THE LETTER MUST BE |
| | HARD COPIES AND SIGNED/SEALED PER THE FOLLOWING: |
| | |
| | |
| | F.S.471.025SEALS.-- |
| | |
| | (1)THE BOARD SHALL PRESCRIBE, BY RULE, ONE OR MORE |
| | FORMS OF SEAL TO BE USED BY LICENSEES. EACH LICENSEE |
| | SHALL OBTAIN AT LEAST ONE SEAL IN THE FORM APPROVED BY |
| | RULE OF THE BOARD AND MAY, IN ADDITION, REGISTER HIS OR |
| | HER SEAL ELECTRONICALLY IN ACCORDANCE WITH SS. |
| | 668.001-668.006. ALL FINAL DRAWINGS, SPECIFICATIONS, |
| | PLANS, REPORTS, OR DOCUMENTS PREPARED OR ISSUED BY THE |
| | LICENSEE AND BEING FILED FOR PUBLIC RECORD AND ALL |
| | FINAL DOCUMENTS PROVIDED TO THE OWNER OR THE OWNER'S |
| | REPRESENTATIVE SHALL BE SIGNED BY THE LICENSEE, DATED, |
| | AND SEALED WITH SAID SEAL. SUCH SIGNATURE, DATE, AND |
| | SEAL SHALL BE EVIDENCE OF THE AUTHENTICITY OF THAT TO |
| | WHICH THEY ARE AFFIXED. DRAWINGS, SPECIFICATIONS, |
| | PLANS, REPORTS, FINAL DOCUMENTS, OR DOCUMENTS PREPARED |
| | OR ISSUED BY A LICENSEE MAY BE TRANSMITTED |
| | ELECTRONICALLY AND MAY BE SIGNED BY THE LICENSEE, |
| | DATED, AND SEALED ELECTRONICALLY WITH SAID SEAL IN |
| | ACCORDANCE WITH SS. 668.001-668.006. |
| | |
| | 2) PLEASE SUBMIT DOCUMENTATION(2 COPIES) INDICATING |
| | THAT THE REGUPOL ACOUSTICAL BARRIER HAS A STC RATING OF |
| | NOT LESS THAN 50 AND COMPLIES WITH ASTM E-90 AND ASTM E |
| | 492: |
| | |
| | 1207.2 AIR-BORNE SOUND. |
| | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES |
| | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM |
| | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION |
| | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) |
| | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM |
| | E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION |
| | ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED |
| | CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR |
| | EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR |
| | OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. |
| | THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT |
| | ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT |
| | FITTING TO THE FRAME AND SILL. |
| | 1207.3 STRUCTURE-BORNE SOUND. |
| | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR |
| | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA |
| | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION |
| | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD |
| | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. |
| | |
| | |