Date Text
2007-11-13 10:02:37****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 REVISED ON 11/27 AFTER SITE VISIT AND FURTHER
 INVESTIGATION:
  
 1.DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3.
  
 2.A-0, OCCUPANT LOAD, PLEASE ROUND UP AS THE OCCUPANT
 LOAD CANNOT BE LESS THAN FBC TABLE 1004.1.2.
  
 3.A2.1, A2.2, SHOWS STAIRS WHICH HAVE BEEN CLOSED OFF
 AT A LOWER LEVEL.THIS CREATES A DEAD END CORRIDOR,
 SEE FBC1016.2.YOU CANNOT HAVE A STAIRWAY WHICH
 APPEARS TO BE AN EXIT WHICH IS BLOCKED OFF.PLEASE
 ADDRESS AS DISCUSSED.
  
 4.A2.2, LEGEND DOES NOT MATCH THE GRAPHIC FOR THE
 WALL.PLEASE CHECK ALL.
  
 5.DOOR D305, A2.2, WHAT IS NEXT TO THE DOOR?THIS
 APPEARS TO BE AN EXISTING STRUCTURAL COLUMN.SEE FBC
 FIGURE 11-25, MANEUVERING CLEARANCE REQUIRED, AND SHOW
 ON THE PLAN.
  
 6.THE PLAN STATES THAT 2ND AND 3RD FLOORS ARE
 BUSINESS OCCUPANCY.PLESAE SEE PERMIT 06090366; A
 PERMIT FOR SECOND FLOOR ALTERATION HAS ALREADY BEEN
 ISSUED AND THE 2ND FLOOR IS ASSEMBLY OCCUPANCY.PLEASE
 SUBMIT CHANGES FOR THE SECOND FLOOR AS A REVISION TO
 THE ISSUED PERMIT, 06090366.
  
 THE SCOPE OF WORK UNDER THIS PERMIT, 07110013, SHOULD
 INCLUDE ONLY THE THIRD FLOOR.
  