| 2007-11-07 18:53:04 | BUILDING PLAN REVIEW |
| | PERMIT: 07100843 |
| | ADD: 10130 NORTHLAKE BLVD |
| | CONT: DOUGLAS M PISARSKI INC. |
| | TEL: (561)662-3818 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST11/7/07 |
| | ACTION: DENIED |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 1B) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 1C) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) |
| | AFTER JULY 1ST, 2007 SHALL BE REVIEWED TO THE 2004 FBC |
| | BUILDING WITH THE 2007 REVISIONS. |
| | |
| | 2)THE NEW SHOWER SHALL BE IN COMPLIANCE WITH FBC |
| | 1210.3. THE WALLS SHALL BE FINISH WITH A SMOOTH |
| | NONABSORBENT SURFACE. PAINT ALONE ON DRYWALL OR DUROCK |
| | IS NOT CONSIDERED NONABSORBENT. WALL WITHIN 2 FEET OF |
| | URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD |
| | NONABSORBENT SURFACE TO A HEIGHT OF 4 FEET ABOVE THE |
| | FINISH FLOOR. FBC1210.2. NOTE: EPOXY PAINT ON DRYWALL |
| | IS NOT CONSIDERED A HARD SURFACE. |
| | |
| | 3)NOTE: THE SPACE OF THE BRACING SHOWS TWO DIFFERENT |
| | MEASUREMENTS ON SHEET A-2. INDICATE CLEARLY WHICH |
| | MEASUREMENT SHALL BE USED. SHEET A-1 SHALL HAVE THE |
| | SAME DIMENSION AS SHEET A-2 FOR THE SPACING OF THE |
| | BRACING. |
| | |
| | 4) NOTE: PROVIDE THE MANUFACTURE SPECIFICATIONS AND |
| | INSTALLATION INFORMATION FOR THE X-RAY MACHINE ON THE |
| | NEW ?LEAD LINED WALL? |
| | |
| | 5)2004 FBC EXISTING 301.5 A DESIGN PROFESSIONAL OR AN |
| | OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS OF |
| | ALTERATION PURSUANT TO SECTIONS 303, 304 AND 305 OF |
| | THIS CODE. |
| | |
| | 6)PROVIDE A WALL SECTION DETAIL SHOWING HOW THE |
| | KENNEL CAGES WILL BE ATTACH TO THE WALL TO PREVENT THEM |
| | FROM OVERTURNING. A STRUCTURAL DETAIL IS ALSO REQUIRED |
| | FOR THE RELOCATION OF THE ELECTRIC WATER HEATER TO THE |
| | CEILING AS STATED ON SHEET A-1. WHAT TYPE OF MATERIALS |
| | IS USED TO CONSTRUCT THE DOG WASH AREA? PROVIDE A |
| | ELEVATION DETAIL SHOWING ALL MATERIALS AND DIMENSIONS |
| | INCLUDING THE STEPS. CONSTRUCTION DOCUMENTS SHALL BE OF |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT |
| | WILL CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1 |
| | FBC* |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |