| 2008-02-27 11:33:48 | FAILED FOR FOLLOWING REASONS: | | | | | | 1.PLEASE SHOW DUMPSTER & ITS ENCLOSURE DETAILS PER CITY | | | OF WPB, &LOCATION ON DWG, LOCATION MUST BE ACCESSIBLE | | | FOR PICKUP TRUCK.PER CITY,DUMPSTER SHOULD BE 13'-8" | | | X 13'-8" MINIMUM. CITY'S DIMENTIONAL SKETCH FOR | | | DUMPSTER IS INCLUDED FOR YOUR USE. ONE OF YOUR DUMPSTER | | | DIMENTION IS 10' WHICH IS NOT ACCEPTABLE UNLESS YOU GET | | | AN APPROVAL LETTER FROM SANITATION DEPT. | | | | | | 2. PLEASE SHOW ON CALCULATION THAT YOU HAVE CONSIDERED | | | FLOOD ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIA | | | AND CROWN OF THE ROAD WHEN YOU DETERMINE THE FIRST | | | FLOOR ELEVATION. FIRST FLOOR ELEVATION SHOULD BE | | | ATLEAST 1 FOOT HIGHER THAN HIGHEST CROWN OF THE ROAD. | | | THE WATER QUALITY CALCULATION MUST BE APPROVED FROM | | | 1000 45TH STREET ENGINEERING BEFORE WE APPROVED . | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|