| 2008-06-10 09:31:52 | RESIDENTIAL ADDITION, BUILDING REVIEWTHIRD |
| | CHECKLIST. |
| | REVIEW UNDER FBC 2004 WITH 2007 REVISIONS. |
| | |
| | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 |
| | FLORIDA STATUTES. |
| | ***NOTE: THIS MAY BE DONE AT TIME OF PRINTING THE |
| | PERMIT TO AVOID EXPIRATION OF DOCUMENT. |
| | |
| | 2-MASONRY GABLE END TO COMPLY WITH SEC.R609.4 OF |
| | 2004 FLORIDA RESIDENTIAL CODE. (REPEAT COMMENT). |
| | DETAILS SHOWN ON PLANS DON'T PROVIDE COMPLETE |
| | INFORMATION. |
| | PROVIDE THE FOLLOWING INFORMATION: |
| | A) SPECIFICATIONS FOR ALL FASTENERS. AND SHOWHOW |
| | ARE THE LOADS TRANSFERRED TO WALLS TO COMPLY WITH SEC. |
| | R601.2OF 2004 FLORIDA RESIDENTIAL CODE. |
| | *** NOTE: SPECIFY LOCATION OF CONNECTOR TA22(L1).SEE |
| | TRUSSS TO1GE TO SEEPOINTS WHERE CONNECTORS ARE |
| | REQUIRED TO PROVIDE UPLIFT RESISTANCE. |
| | |
| | 3- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE |
| | 9B-72 FOR: |
| | A) AWNING WINDOW. (IF THIS IS THE TYPE OF WINDOW TO |
| | BE USED ON MASTER BEDROOM EAST WALL. (REPEAT |
| | COMMENT). |
| | *** NOTE: FLOOR PLAN CALLS FOR 22SH WINDOW, WHILENEW |
| | EAST ELEVATIONSHOWS A 36"X20" AWNING WINDOW. CLARIFY |
| | AS REQUIRED. IN ADDITION, CLARIFY WHY SUBMITTING2 |
| | DIFFERENT PRODUCT APPROVALS FOR SINGLE HUNG WINDOWS. |
| | TWO FROM LAWSON INDUSTRIES AND ONE FROM SECURITIES |
| | IMPACT WINDOWS? |
| | |
| | B) FRENCH DOORS. |
| | ***NOTE: ONLY ONE COPY WAS SUBMITTED. NEED TO SUBMIT |
| | TWO COPIES. |
| | |
| | C) ALL SIMPSON OR USP STRUCTURAL CONNECTORS |
| | SPECIFIED ON PLANS AND DETAILS. (REPEAT COMMENT). |
| | ***NOTE: PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE |
| | AND PAGE WHERE CONNECTOR IS SHOWN. SOME PRODUCT |
| | APPROVALS SUBMITTED ARE FOR CONNECTORS NOT SPECIFIED ON |
| | PLANS. EG: NOA 03-0219.02 IF FOR UGTS AND LUGT2 |
| | CONNECTORS. WHERE ARE THESE CONNECTORS SPECIFIED ON |
| | PLANS? |
| | |
| | D) PRECAST LINTELS. |
| | ***NOTE: ONLY THE COVER PAGE OF NOA 06-0222.01 WAS |
| | SUBMITTED. NEED TO PROVIDE COMPLETE NOA AND PROVIDE TWO |
| | COPIES. |
| | |
| | 4- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT |
| | SIGNING AND SEALING)ALL PRODUCT APPROVALS AS REQUIRED |
| | BYSEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 5- SURVEY: |
| | A) REVISE ADDITION BUILDING DIMENSION TO MATCH |
| | REVISED FLOOR PLANS. (REPEAT COMMENT). |
| | |
| | B) NEED SURVEYOR'S ORIGINAL SIGNATURE (REPEAT |
| | COMMENT).SEC. 61G17-7.0025 FLORIDA ADMINISTRATIVE |
| | CODE AND CHAPTER 472FLORIDA STATUTE. |
| | |
| | 6- ENERGY CALCULATIONS: |
| | A) ITEM #7A)IS USING A SPECIFIC U-FACTOR OF U=1.7. |
| | PROVIDE PROOF THAT WINDOWS AND DOORS MEET THIS SPECIFIC |
| | U FACTOR. OTHERWISE USE THE DEFAULT VALUE. SEE SEC. |
| | 13-104.4.5 FBC 2004. |
| | |
| | 7- TRUSS PACKAGE: |
| | A) TRUSS ENGINEER TO COMPLY WITH SEC. 61G15-31.003. |
| | NEED TO WRITE DESIGNER OF RECORD NAME AND ALL SHEETS |
| | NEED TO BE NUMBERED AND COORDINATED WITH THE INDEX |
| | SHEET AND PROVIDE THE TRUSS ENGINEER INFORMATION ON |
| | EACH SHEET. (REPEAT COMMENT). |
| | |
| | B) INDEX SHEET NEEDS TO HAVE ENGINEER'S ORIGINAL |
| | SIGNATURE. NOT COPY.SEC. 61G15-31.003 FLORIDA |
| | ADMINISTRATIVE CODE. (REPEAT COMMENT). |
| | |
| | C) REVISE BUILDING DIMENSIONS TO MATCH REVISED |
| | PLANS. (REPEAT COMMENT). |
| | |
| | ***ONE SET WILL BE RETAINED IN THIS OFFICE TO BE SEND |
| | TO THE BOARD OF ENGINEERS. |
| | |
| | 8-ARCHITECT TO REVIEW AND APPROVEREVISED TRUSS |
| | PACKAGE PRIOR TO SUBMITTAL TO THIS OFFICE. |
| | |
| | 9- SHEET A-1: |
| | A) UPDATE ALL REFERENCE STANDARDS SHOWN ON THE |
| | FOUNDATION NOTES. (REPEAT COMMENT). SEE CHAPTER 43 OF |
| | 2004 FLORIDA RESIDENTIAL CODE FOR CORRECT YEAR TO BE |
| | REFERENCED AND REVISE AS REQUIRED. |
| | |
| | B) CLARIFYTHICKNESS OF CONCRETE SLAB. BUILDING |
| | SECTION 2 ON SHEET A-4 CALLS FOR 6" CONCRETE SLAB, |
| | WHILE FOUNDATION PLAN CALLS FOR 4" CONCRETE SLAB. |
| | REVISE AS REQUIRED TO MATCH. (REPEAT COMMENT). |
| | |
| | C) FOOTING DETAIL 1/A-1 DOESN'T MATCHFOOTING SHOWN |
| | ON FOUNDATIONPLAN AND IT DOESN'T SPECIFY SPACING FOR |
| | DOWELS.PROVIDE COMPLETE AND CORRECT INFORMATION. |
| | (REPEAT COMMENT). |
| | |
| | 10- SHEET A-2: |
| | A) BUILDING SIZE WAS REVISED. NEED TO REVISE AREA |
| | CALCULATIONS ALSO. (REPEAT COMMENT). |
| | |
| | B)COMPLY WITH SEC. R311.5.3 OF 2004 FLORIDA |
| | RESIDENTIAL CODE.PROVIDE DIMENSIONS FOR RISERS AND |
| | TREADS AND REVISE DRAWING ACCORDINGLY. (REPEAT |
| | COMMENT). |
| | *** FLOOR PLAN SHOWS THREE RISERS BUT SPECIFIES(2) |
| | NEW 7.5" R STEPS.REVISE AS REQUIRED AND ALSO SPECIFY |
| | SIZE OF TREAD TO VERIFY COMPLIANCE WITH CODE SECTION |
| | CITED ABOVE. |
| | |
| | C) CLARIFY IF WINDOW ON MASTER BEDROOM EAST WALL IS |
| | A SINGLE HUNG WINDOW OR AWNING WINDOW. SEE EAST |
| | ELEVATION AND REVISE AS REQUIRED. (REPEAT COMMENT). |
| | |
| | 11- SHEET A-4: |
| | A)COORDINATELOADS SHOWN ON TYPICAL END DETAIL |
| | AND LOADS SHOWN ON ROOF FRAMING NOTE #3 AND ON NEW ROOF |
| | LOADING TABLE. (REPEAT COMMENT). |
| | |
| | B)SPECIFY ROOF SHEATHING NAIL TYPE AND SPACING TO |
| | BE USED INCLUDING ON ROOF ZONE #3.SEE SEC. R803.2.3.1 |
| | OF 2004 FLORIDA RESIDENTIAL CODE FOR MIN. TYPE AND |
| | SPACING TO BE USED.REVISE INFORMATION ON ROOF NAILING |
| | NOTE, AND ON BOTH BUILDING SECTIONS TO MATCH. (REPEAT |
| | COMMENT). |
| | |
| | C)DETAIL SECTION#4 NEEDSTO SPECIFY ALL |
| | FASTENERS FORTOP AND BOTTOM OF 2X8 KNEE WALL. SEC. |
| | 106.1.2 CITY AMENDMENTS TO FBC 2004 TO VERIFY |
| | COMPLIANCE WITH WIND LOADS OF SEC. R301 OF 2004 FLORIDA |
| | RESIDENTIAL CODE. (REPEAT COMMENT). |
| | *** NOTE:IN ADDITION, THIS SECTION DOESN'T MATCH |
| | INFORMATION SHOWN ON ROOF FRAMING PLAN AND TRUSS |
| | PACKAGE.(REPEAT COMMENT). |
| | |
| | D) REVISE ROOF FRAMING NOTE #6.FLORIDA BUILDING |
| | CODE DOESN'T SPECIFY CONNECTORS. |
| | |
| | NOTE: ONE SET OF PLANS WILL BE RETAINED IN THIS OFFICE |
| | FOR FUTURE REFERENCE. ARCHITECT TO SEE ATTACHED COPY OF |
| | FLORIDA STATUTE 553.80(2)(B) REGARDING MULTIPLE PLAN |
| | REVIEWS AND FEES. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |