Plan Review Notes
Plan Review Notes For Permit 07100688
Permit Number 07100688
Review Stop B
Sequence Number 3
Notes
Date Text
2008-06-10 09:31:52RESIDENTIAL ADDITION, BUILDING REVIEWTHIRD
 CHECKLIST.
 REVIEW UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTES.
 ***NOTE: THIS MAY BE DONE AT TIME OF PRINTING THE
 PERMIT TO AVOID EXPIRATION OF DOCUMENT.
  
 2-MASONRY GABLE END TO COMPLY WITH SEC.R609.4 OF
 2004 FLORIDA RESIDENTIAL CODE. (REPEAT COMMENT).
 DETAILS SHOWN ON PLANS DON'T PROVIDE COMPLETE
 INFORMATION.
 PROVIDE THE FOLLOWING INFORMATION:
 A) SPECIFICATIONS FOR ALL FASTENERS. AND SHOWHOW
 ARE THE LOADS TRANSFERRED TO WALLS TO COMPLY WITH SEC.
 R601.2OF 2004 FLORIDA RESIDENTIAL CODE.
 *** NOTE: SPECIFY LOCATION OF CONNECTOR TA22(L1).SEE
 TRUSSS TO1GE TO SEEPOINTS WHERE CONNECTORS ARE
 REQUIRED TO PROVIDE UPLIFT RESISTANCE.
  
 3- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) AWNING WINDOW. (IF THIS IS THE TYPE OF WINDOW TO
 BE USED ON MASTER BEDROOM EAST WALL. (REPEAT
 COMMENT).
 *** NOTE: FLOOR PLAN CALLS FOR 22SH WINDOW, WHILENEW
 EAST ELEVATIONSHOWS A 36"X20" AWNING WINDOW. CLARIFY
 AS REQUIRED. IN ADDITION, CLARIFY WHY SUBMITTING2
 DIFFERENT PRODUCT APPROVALS FOR SINGLE HUNG WINDOWS.
 TWO FROM LAWSON INDUSTRIES AND ONE FROM SECURITIES
 IMPACT WINDOWS?
  
 B) FRENCH DOORS.
 ***NOTE: ONLY ONE COPY WAS SUBMITTED. NEED TO SUBMIT
 TWO COPIES.
  
 C) ALL SIMPSON OR USP STRUCTURAL CONNECTORS
 SPECIFIED ON PLANS AND DETAILS. (REPEAT COMMENT).
 ***NOTE: PROVIDE ONLY THE PRODUCT APPROVAL COVER PAGE
 AND PAGE WHERE CONNECTOR IS SHOWN. SOME PRODUCT
 APPROVALS SUBMITTED ARE FOR CONNECTORS NOT SPECIFIED ON
 PLANS. EG: NOA 03-0219.02 IF FOR UGTS AND LUGT2
 CONNECTORS. WHERE ARE THESE CONNECTORS SPECIFIED ON
 PLANS?
  
 D) PRECAST LINTELS.
 ***NOTE: ONLY THE COVER PAGE OF NOA 06-0222.01 WAS
 SUBMITTED. NEED TO PROVIDE COMPLETE NOA AND PROVIDE TWO
 COPIES.
  
 4- ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT
 SIGNING AND SEALING)ALL PRODUCT APPROVALS AS REQUIRED
 BYSEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 5- SURVEY:
 A) REVISE ADDITION BUILDING DIMENSION TO MATCH
 REVISED FLOOR PLANS. (REPEAT COMMENT).
  
 B) NEED SURVEYOR'S ORIGINAL SIGNATURE (REPEAT
 COMMENT).SEC. 61G17-7.0025 FLORIDA ADMINISTRATIVE
 CODE AND CHAPTER 472FLORIDA STATUTE.
  
 6- ENERGY CALCULATIONS:
 A) ITEM #7A)IS USING A SPECIFIC U-FACTOR OF U=1.7.
 PROVIDE PROOF THAT WINDOWS AND DOORS MEET THIS SPECIFIC
 U FACTOR. OTHERWISE USE THE DEFAULT VALUE. SEE SEC.
 13-104.4.5 FBC 2004.
  
 7- TRUSS PACKAGE:
 A) TRUSS ENGINEER TO COMPLY WITH SEC. 61G15-31.003.
 NEED TO WRITE DESIGNER OF RECORD NAME AND ALL SHEETS
 NEED TO BE NUMBERED AND COORDINATED WITH THE INDEX
 SHEET AND PROVIDE THE TRUSS ENGINEER INFORMATION ON
 EACH SHEET. (REPEAT COMMENT).
  
 B) INDEX SHEET NEEDS TO HAVE ENGINEER'S ORIGINAL
 SIGNATURE. NOT COPY.SEC. 61G15-31.003 FLORIDA
 ADMINISTRATIVE CODE. (REPEAT COMMENT).
  
 C) REVISE BUILDING DIMENSIONS TO MATCH REVISED
 PLANS. (REPEAT COMMENT).
  
 ***ONE SET WILL BE RETAINED IN THIS OFFICE TO BE SEND
 TO THE BOARD OF ENGINEERS.
  
 8-ARCHITECT TO REVIEW AND APPROVEREVISED TRUSS
 PACKAGE PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 9- SHEET A-1:
 A) UPDATE ALL REFERENCE STANDARDS SHOWN ON THE
 FOUNDATION NOTES. (REPEAT COMMENT). SEE CHAPTER 43 OF
 2004 FLORIDA RESIDENTIAL CODE FOR CORRECT YEAR TO BE
 REFERENCED AND REVISE AS REQUIRED.
  
 B) CLARIFYTHICKNESS OF CONCRETE SLAB. BUILDING
 SECTION 2 ON SHEET A-4 CALLS FOR 6" CONCRETE SLAB,
 WHILE FOUNDATION PLAN CALLS FOR 4" CONCRETE SLAB.
 REVISE AS REQUIRED TO MATCH. (REPEAT COMMENT).
  
 C) FOOTING DETAIL 1/A-1 DOESN'T MATCHFOOTING SHOWN
 ON FOUNDATIONPLAN AND IT DOESN'T SPECIFY SPACING FOR
 DOWELS.PROVIDE COMPLETE AND CORRECT INFORMATION.
 (REPEAT COMMENT).
  
 10- SHEET A-2:
 A) BUILDING SIZE WAS REVISED. NEED TO REVISE AREA
 CALCULATIONS ALSO. (REPEAT COMMENT).
  
 B)COMPLY WITH SEC. R311.5.3 OF 2004 FLORIDA
 RESIDENTIAL CODE.PROVIDE DIMENSIONS FOR RISERS AND
 TREADS AND REVISE DRAWING ACCORDINGLY. (REPEAT
 COMMENT).
 *** FLOOR PLAN SHOWS THREE RISERS BUT SPECIFIES(2)
 NEW 7.5" R STEPS.REVISE AS REQUIRED AND ALSO SPECIFY
 SIZE OF TREAD TO VERIFY COMPLIANCE WITH CODE SECTION
 CITED ABOVE.
  
 C) CLARIFY IF WINDOW ON MASTER BEDROOM EAST WALL IS
 A SINGLE HUNG WINDOW OR AWNING WINDOW. SEE EAST
 ELEVATION AND REVISE AS REQUIRED. (REPEAT COMMENT).
  
 11- SHEET A-4:
 A)COORDINATELOADS SHOWN ON TYPICAL END DETAIL
 AND LOADS SHOWN ON ROOF FRAMING NOTE #3 AND ON NEW ROOF
 LOADING TABLE. (REPEAT COMMENT).
  
 B)SPECIFY ROOF SHEATHING NAIL TYPE AND SPACING TO
 BE USED INCLUDING ON ROOF ZONE #3.SEE SEC. R803.2.3.1
 OF 2004 FLORIDA RESIDENTIAL CODE FOR MIN. TYPE AND
 SPACING TO BE USED.REVISE INFORMATION ON ROOF NAILING
 NOTE, AND ON BOTH BUILDING SECTIONS TO MATCH. (REPEAT
 COMMENT).
  
 C)DETAIL SECTION#4 NEEDSTO SPECIFY ALL
 FASTENERS FORTOP AND BOTTOM OF 2X8 KNEE WALL. SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004 TO VERIFY
 COMPLIANCE WITH WIND LOADS OF SEC. R301 OF 2004 FLORIDA
 RESIDENTIAL CODE. (REPEAT COMMENT).
 *** NOTE:IN ADDITION, THIS SECTION DOESN'T MATCH
 INFORMATION SHOWN ON ROOF FRAMING PLAN AND TRUSS
 PACKAGE.(REPEAT COMMENT).
  
 D) REVISE ROOF FRAMING NOTE #6.FLORIDA BUILDING
 CODE DOESN'T SPECIFY CONNECTORS.
  
 NOTE: ONE SET OF PLANS WILL BE RETAINED IN THIS OFFICE
 FOR FUTURE REFERENCE. ARCHITECT TO SEE ATTACHED COPY OF
 FLORIDA STATUTE 553.80(2)(B) REGARDING MULTIPLE PLAN
 REVIEWS AND FEES.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712