| 2007-11-05 14:00:36 | 2004 FBC W/2007 REVISIONS |
| | LEVEL 2 ALTERATIONS |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2) THE PRINTED NAME AND SIGNATURE OF THE PERSON |
| | RESPONSIBLE FOR THE DESIGN IS REQUIRED ON EACH DRAWING. |
| | FBC * 106.1.2 QUALITY OF PLANS |
| | BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 INCH |
| | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE |
| | MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH THROUGH |
| | DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND |
| | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS |
| | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH |
| | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR |
| | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. |
| | |
| | 3) CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| | LAWS, SEE F.B.C. 106.1.1 CITY AMENDMENTS. |
| | |
| | 4) PROVIDE DIMENSIONS ON THE PLANS FOR THE NEW WALLS, |
| | OPENINGS, ROOMS, WINDOWS, DOORS, ETC.SPECIFY THE |
| | WINDOW TYPES AND SIZES ON THE DRAWINGS. FBC 106.1.1 |
| | CITY AMENDMENTS. |
| | |
| | 5) PROVIDE WALL SECTIONS FOR INTERIOR WALLS. INDICATE |
| | THE MATERIAL, SIZE AND SPACING OF FRAMING.F.B.C. |
| | 106.1.1 CITY AMENDMENTS. |
| | |
| | 6) THE EXTERIOR WALL FRAMING DETAIL FOR THE NEW WINDOWS |
| | AND DOORS DOES NOT CONTAIN ENOUGH INFORMATION. SPECIFY |
| | THE FRAMING MATERIAL, SPACING, HEADER SIZES, OPENING |
| | SIZES, NUMBER OF JACKS, INSULATION, INTERIOR AND |
| | EXTERIOR WALL COVERINGS, SHOW ADEQUATE SUBSTRATE FOR |
| | ATTACHING STORM PANELS, SPECIFY THE CONNECTORS THAT |
| | WILL BE USED. BE SPECIFIC. FBC 106.1.1 CITY |
| | AMENDMENTS. |
| | |
| | 7)FBC 1606.1.4SHUTTERS. |
| | INSTALLATION/DESIGN INFORMATION |
| | REQUIRED.SUBMIT AN INSTALLATION |
| | SCHEDULE INCLUDING THE FOLLOWING |
| | DETAILS: |
| | (A) BUILDING CONSTRUCTION TYPE (EG CBS) |
| | (B) BUILDING (OR INSTALLATION) HEIGHT |
| | (C) DESIGN PRESSURE FOR EACH OPENING |
| | (D) OPENING SIZES |
| | (E) SHUTTER SPAN (VERTICAL/HORIZONTAL?) |
| | (F) ANCHOR TYPE, SIZE AND SPACING |
| | A FORM IS AVAILABLE FROM THIS OFFICE |
| | GIVING THE RECOMMENDED INSTALLATION |
| | SCHEDULE FORMAT.SUBMIT THE ABOVE |
| | INFORMATION WHICH IS REQUIRED FOR |
| | REVIEW. |
| | |
| | 8) THE PRODUCT APPROVAL SUBMITTED FOR THE FRENCH DOOR |
| | IS FOR A SINGLE OUTSWING DOOR WITH SIDELITES (OXO). THE |
| | DRAWINGS INDICATE A DOUBLE OUTSWING DOOR WITH NO |
| | SIDELITES INDICATED. PLEASE CLARIFY. |
| | |
| | 9) THE PRODUCT APPROVAL SUBMITTED FOR THE STORM PANELS |
| | IS INCOMPLETE. THE INSTALLATION DRAWINGS 05-078 SHEETS |
| | 1-15 ARE MISSING. SEE RULE FAC 9B-72. |
| | |
| | 10) THE PRODUCT APPROVALS SUBMITTED FOR THE JELD-WEN |
| | CASEMENT AND AWNING WINDOWS DO NOT SPECIFY THE DESIGN |
| | PRESSURES. THE DESIGN PRESSURES ARE REQUIRED TO |
| | DETERMINE IF THE WINDOWS MEET THE COMPONENT AND |
| | CLADDING PRESSURES FOR THE STRUCTURE. SEE FBC TABLE |
| | R301.2(2). |
| | |
| | 11)106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | - ROBERT MCDOUGAL |