 DENIED
  
 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*
  
 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $163.33 FOR
 INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS
 REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW
  
 4)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE,
 AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
  
 5)MAKE CORRECTIONS TO ENERGY CALCULATIONS PLEASE NOTE
 THAT THE MIN WALL INSULATION ON THE SHORT FORM IS R-5
 BUT CALCULATIONS SHOULD MATCH THE DRAWINGS WHICH STATE
 ON SHEET 2.1 THAT R-6 BATT WILL BE USED ON WALLS.
  
 6)WINDOW PRODUCT APPROVALS ARE A COMBINATION OF
 DIFFERENT INFORMATION, THE STATE OF FLORIDA APPROVAL IS
 FOR MANY DIFFERENT MODELS ALL WITH DIFFERENT PRESSURE
 MAXIMUMS, THE STC TEST IS FOR A MODEL THAT IS NOT IN
 THE PRODUCT APPROVAL, THE MIAMI-DADE IS FORANOTHER
 MODEL AND THE DRAWINGS STATE TO USE TWO MORE MODELS.
 PLEASE PICK THE TYPE OF WINDOW AND SUBMIT THE PRODUCT
 APPROVAL FOR THAT WINDOW ONLY. (IF THE STC VALUE MEETS
 THE REQUIREMENTS THAT YOU NEED THAT IS OK BUT FOR PLAN
 REVIEW NO REQUIREMENTS NEED TO BE MET AND THE
 INFORMATION IS NOT REQUIRED)
  
 7)WINDOW PRODUCT APPROVAL FROM MIAMI-DADE IS FOR
 NON-IMPACT WINDOWS THEREFORE IMPACT PROTECTION WILL BE
 REQUIRED. PLEASE SUBMIT SHUTTER PRODUCT APPROVALS.
  
 8)DOOR PRODUCT APPROVALS ARE FOR SINGLE DOOR ONLY AND
 IS FOR A 7'-0" TALL DOOR. PLEASE SUBMIT PRODUCT
 APPROVAL FOR THE DOUBLE DOORS AND MEET THE 6'-8" THAT
 YOU REQUIRE.
  
 9)NO PRODUCT APPROVALS WERE SUBMITTED FOR ASPHALT
 SHINGLES, PROPOSED SKYLIGHTS OR STORM SHUTTERS
  
 10)MAXIMUM RISER HEIGHT AT DOORS TO LAUNDRY ROOM IS 7
 3/4" PLEASE MAKE CORRECTION ON DRAWINGS
  
 11)SUBMIT ENGINEERED TRUSS DRAWINGS THAT COMPLY WITH
 R802.10.1 FBC WITH PERMIT APPLICATION OR BEFORE
 INSTALLATION THAT HAVE BEEN REVIEWED AND APPROVED BY
 THE DESIGNER OF RECORD
  
 12)CORRECT MIN ROOF SHEATHING ATTACHMENT FOR ZONE 3
 PER R803.2.3.1 FBC RES.
  
 13)PROVIDE POURED/REINFORCED BLOCK CELL IN EXISTING
 BUILDING AT LOCATION OF EXISTING KITCHEN AND BATH AND
 THE INTERSECTION OF L-10 LINTEL THAT CARRIE ROOF LOAD
 OVER CONCRETE PATIO.
  
 14)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS OF
 NEW DRAWINGS AND INCLUDE 1 COPY OF THE OLD PAGES ONLY
 FOR REFERENCE
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  