| Plan Review Notes For Permit 07100375 |
| Permit Number |
07100375 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2007-10-29 11:38:45 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.A RESIDENTIAL CONTRACTOR LICENSE IS LIMITED TO | | | CONSTRUCTION, REMODELING, DEMOLITION, REPAIR OR | | | IMPROVEMENT OF ONE, TWO, OR THREE FAMILY RESIDENCES. | | | THIS JOB DOES NOT APPEAR TO BE WITHIN THE SCOPE OF A | | | RESIDENTIAL CONTRACTOR LICENSE. | | | | | | 2.DECLARE THE USE OF THIS RAMP.IT APPEARS TO BE A | | | LOADING RAMP, BUT IF IT IS A PEDESTRIAN RAMP, | | | ACCESSIBILITY REQUIREMENTS OF FBC11-4.8 MUST BE SHOWN | | | ON THE PLAN. | | | | | | 3.DECLARE OCCUPANCY OF THE BUILDING, FBC CHAPTER 3. | | | CODE COMPLIANCE CANNOT BE DETERMINED WITHOUT THIS | | | INFORMATION. | | | | | | 4.SEE FBC1012.1 REGARDING GUARDRAILS; REVISE PLANS TO | | | SHOW COMPLIANCE. | | | | | | 5.DECLARE GOVERNING CODE. | | | | | | 6.DECLARE WIND DESIGN CRITERIA, FBC1603.1.4. | | | | | | 7. C-C SHOWS THE EXISTING BUILDING AT 3'7" ABOVE GRADE, | | | A-A (NOTE THAT ONLY ONE "A" SHOWN ON THIS CROSS SECTION | | | ON THE PLAN) SHOWS 7'2".CLARIFY. | | | | | | |
|