2008-08-05 15:24:17****************PROVISO*****************
 A} PER FBC-2004 CHAPTER 11, FLORIDA ACCESSIBILITY CODE
 SECTION 11-4.1.3(10)(A) WHERE ONLY ONE DRINKING
 FOUNTAIN IS PROVIDED ON A FLOOR, THERE SHALL BE A
 DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO INDIVIDUALS
 WHO USE WHEELCHAIRS IN ACCORDANCE WITH SECTION 11-4.15
 AND ONE ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING
 OR STOOPING.(THIS CAN BE ACCOMMODATED BY THE USE OF A
 HI-LO FOUNTAIN OR BY SUCH OTHER MEANS AS WOULD ACHIEVE
 THE REQUIRED ACCESSIBILITY FOR EACH GROUP ON EACH
 FLOOR).
  
 B} A CLEANOUT IS REQUIRED AT THE BASE OF THE DRINKING
 FOUNTAIN WASTE STACK. PER FBC-2004 PLUMBING SECTION
 708.3.5 BASE OF STACK.
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER