| Plan Review Notes For Permit 07100288 |
| Permit Number |
07100288 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2007-10-29 11:22:01 | | | | | | | BUILDING PROVISO: | | | 07100288 | | | 525 S. FLAGLER DR | | | | | | | | | TO BE IN PLACE AT C.O.: | | | | | | | | | PUBLIC POOLS | | | 424.1.3.1.9 ALL PUBLIC POOLS SHALL BE SURROUNDED BY A | | | MINIMUM 48" IN HEIGHT FENCE. A SELF LATCHING SELF | | | CLOSING LOCKABLE GATE OF 48" MINIMUM HEIGHT WITH THE | | | LATCH LOCATED NEAR THE TOP. SAFETY COVERS THAT COMPLY | | | WITH ASTM F 1346 DO NOT SATIFY THIS REQUIREMENT. | | | | | | 13-412.1ABC2.6.2 POOL COVERS. HEATED POOLS SHALL BE | | | EQUIPPED WITH A VAPOR RETARDANT POOL COVER ON OR AT THE | | | WATER SURFACE. POOLS HEATED TO MORE THAN 90 DEGREES | | | (F) | | | SHALL HAVE A POOL COVER WITH A MINIMUM INSULATION VALUE | | | OF R-12. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE | | | APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|