| 2007-11-30 16:22:34 | |
| | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 0710119 |
| | ADD: 2223 PBL BLVD |
| | CONT: CARLO MERCURIO |
| | TEL: (561) 329-8167 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 2ND |
| | ACTION: DENIED |
| | 11/9/07 |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 1B) **OK** |
| | |
| | 1C) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 1D) **OK** |
| | |
| | 2)**OK** |
| | |
| | 3)**OK** |
| | . ------------------------------------- |
| | ) NUMBER OF FLOORS |
| | ) NUMBER OF ROOMS |
| | |
| | 4)THE PROPOSED LAYOUT PLAN ON SHEET A-2 SHALL |
| | INDICATE THE DIMENSION OF EACH WALL AND ROOM. EACH WALL |
| | SHALL BE LABELED TO INDICATE THE CONSTRUCTION TYPE. |
| | SHOW HOW THE WALLS WHICH ARE NOT ATTACHED TO THE DECK |
| | ABOVE WILL BE BRACED. CONSTRUCTION DOCUMENTS SHALL BE |
| | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE |
| | AND EXTENT OF THE WORK PROPOSED. THE FLOOR AND SUITE |
| | NUMBER SHALL APPEAR ON THE APPLICATION AND ON EACH |
| | SHEET OF THE PLANS. FBC106.1.1**THE NEW HAND WRITTEN |
| | INFORMATION ON THE DRAWINGS IS NOT ALLOWED. DUE TO THE |
| | FACT, THAT OTHER CHANGES MAY BE MADE WITHOUT THE |
| | APPROVAL OF THE DESIGNER OF RECORD THIS PRACTICE IN NOT |
| | ACCEPTABLE PER 106.1.3 THE BUILDING OFFICIAL MAY |
| | ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR |
| | PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE |
| | CONFORMITY TO ITS RECORD RETENTION PROGRAM. THE |
| | DRAWINGS ALSO CONTAIN ILLEGIBLE INFORMATION, SEE ALL |
| | SHEETS. |
| | |
| | 5)106.3.3* PRODUCT APPROVALS- 2004. THOSE PRODUCTS |
| | THAT ARE REGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY |
| | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. SUBMIT THE PRODUCT APPROVAL |
| | FOR THE NEW DOOR, INDICATE WHICH DOOR SYSTEM WILL BE |
| | USED FROM THE PRODUCT APPROVAL PACKAGE BY CIRCLING THE |
| | INFORMATION. **THE PRODUCT APPROVAL FOR THE PRE-CAST |
| | LENTIL IS MISSING FROM THE PACKAGE. FBC 2107.2.3 THE |
| | MINIMUM LENGTH OF LAP SPLICES FOR REINFORCING BARS IN |
| | TENSION OR COMPRESSION SHALL NOT BE LESS THAN 40 BAR |
| | DIAMETERS SEE DOOR OPENING DETAIL SHEET A-3** |
| | |
| | **THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND NEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC** |
| | |
| | **AN EXISTING BUILDING BEING DEMOLISH OR RENOVATED |
| | SHALL HAVE AN ASBESTOS NOTIFICATION STATEMENT POSTED AT |
| | THE SITE WHICH INDICATE THE OWNER?S OR OPERATOR?S |
| | RESPONSIBILITY TO COMPLY WITH THE PROVISIONS OF SECTION |
| | 469.003, FLORIDA STATUTES AND NOTIFY THE DEPARTMENT OF |
| | ENVIROMENTAL PROTECTION OF HIS OR HER INTENTIONS TO |
| | REMOVE ASBESTOS, WHEN APPLICABLE, IN ACCORDANCE WITH |
| | STATE AND FEDERAL LAW. FBC 105.9** |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |