| 2007-10-25 07:50:15 | 2004 FBC W/2007 REVISIONS | | | INSTALL 1/2 BATH UNDER STAIRS | | | | | | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) PROPOSED WORK DOES NOT COMPLY WITH R305.1 MINIMUM | | | HEIGHT. | | | HABITABLE ROOMS, HALLWAYS, CORRIDORS, BATHROOMS, TOILET | | | ROOMS, LAUNDRY ROOMS AND BASEMENTS SHALL HAVE A CEILING | | | HEIGHT OF NOT LESS THAN 7 FEET (2134 MM). THE REQUIRED | | | HEIGHT SHALL BE MEASURED FROM THE FINISH FLOOR TO THE | | | LOWEST PROJECTION FROM THE CEILING EXCEPTIONS: 4. | | | BATHROOMS SHALL HAVE A MINIMUM CEILING HEIGHT OF 6 FEET | | | 8 INCHES (2036 MM) OVER THE FIXTURE AND AT THE FRONT | | | CLEARANCE AREA FOR FIXTURES AS SHOWN IN FIGURE R307.2 . | | | | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|