| 2007-11-11 09:44:16 | REVIEW #: 1ST |
| | ACTION: DENIED |
| | |
| | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS FBC |
| | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH |
| | |
| | 1. NO LEVEL OF ALTERATION HAS BEEN DECLARED ON PLANS. |
| | THE DESIGN PROFESSIONAL MUST ELECT ONE OR A COMBINATION |
| | OF LEVELS OF ALTERATION PURSUANT TO SECTIONS 303, 304 |
| | AND 305 OF THIS CODE. SEE FBC,EB 301.5. |
| | |
| | 2. THIS APPEARS TO BE A LEVEL 2 ALTERATION AS THERE IS |
| | RECONFIGURATION OF SPACES SHOWN ON PLANS. IN LEVEL 2 |
| | ALTERATIONS, RECONFIGURED SPACES INTENDED FOR OCCUPANCY |
| | SHALL BE PROVIDED WITH MECHANICAL VENTILATION OR |
| | EXHAUST IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, |
| | MECHANICAL IN ACCORDANCE WITH FBC,EB 609.1. SHOW |
| | OUTSIDE AIR CALCULATIONS BASED ON OCCUPANCY |
| | CLASSIFICATION, OCCUPANT LOADS AND VENTILATION RATES AS |
| | REQUIRED BY FBC,M TABLE 403.3. BE SURE TO INCLUDE |
| | RESTROOM EXHAUST. |
| | |
| | 3. ALTERATIONS SUBJECT TO THIS CHAPTER SHALL COMPLY |
| | WITH THE REQUIREMENTS OF CHAPTER 13 OF THE FLORIDA |
| | BUILDING CODE, BUILDING IN ACCORDANCE WITH FBC,EB |
| | 611.1. BASIC PRESCRIPTIVE REQUIREMENTS SHALL BE MET FOR |
| | ALL BUILDINGS WITH REGARD TO NEW COMPONENTS BEING |
| | INSTALLED OR COMPONENTS BEING RETROFITTED (SUCH AS |
| | LIGHTING, NEW WINDOW AND NEW DUCTS) IN ACCORDANCE WITH |
| | FBC 13-400.1. PROVIDE DOCUMENTATION AND SUFFICIENT |
| | NOTATION ON PLAN TO DEMONSTRATE COMPLIANCE WITH THESE |
| | SECTIONS. |
| | |