| 2008-01-15 18:15:35 | |
| | |
| | |
| | DENIED |
| | |
| | THE FOLLOWING COMMENTS WERE NOT ADDRESS FROM THE 1ST |
| | REVIEW: |
| | |
| | 1)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE |
| | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS |
| | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN |
| | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 |
| | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C |
| | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND |
| | PRESSURES ACCORDINGLY.*** BE SURE TO CHECK PRODUCT |
| | APPROVALS FOR COMPLIANCE WITH INCREASED DESIGN |
| | PRESSURE*** |
| | *********NOTE THIS IS AN EXPOSURE C PLEASE ADJUST WIND |
| | INFORMATION AND OPENING DESIGN PRESSURES********* |
| | |
| | 2)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| | EACH PRODUCT APPROVAL THATIS RELEVANT PER 9B-72. |
| | THESE SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER |
| | PAGES, AND THE PRODUCT NOA THAT LISTS THE SYSTEM |
| | COMPONENTS/ FASTENER LIST PAGES. ALL CAN BE FOUND ON |
| | WWW.FLORIDABUILDING.ORG ****PROVIDE PRODUCT |
| | APPROVALS FOR THE CASTCRETE LINTELS, CONNECTOR |
| | STRAPS/TIES, ETC.**** |
| | ***********NOTE PROVIDE LINTEL AND CONNECTOR PRODUCT |
| | APPROVAL SHEETS, ALSO NOTE THAT SEVERAL DIFFERENT |
| | PRODUCT APPROVALS WERE SUBMITTED IN PACKAGE FOR WINDOWS |
| | AND DOORS . PLEASE SUBMIT ONLY 2 COPIES OF EACH PRODUCT |
| | THAT WILL BE USED MAKING SURE THAT THEY ARE LEDGIBLE |
| | AND EACH IS REVIEWED AND APPROVED FOR USE BY THE |
| | DESIGNER OF RECORD*********** |
| | |
| | 3)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | |
| | 9)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT |
| | SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, AND A |
| | COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 10)SHOW THAT NEW ROOF/CEILING THAT HAS BECOME PART OF |
| | CONDITIONED SPACE WILL RECEIVE INSULATION |
| | **********NOTE SUBMIT TWO COPIES OF ENERGY CALC'S PER |
| | 13-101.2.2 FBC. BE SURE THAT THEY ARE SIGNED AND DATED |
| | BY PREPARER AND OWNER/AGENT PRIOR TO SUBMITTAL. SMALL |
| | ADDITIONS UNDER 600 SQ. FT CAN USE SHORT FORM 600C-04R |
| | BUT PLEASE NOTE THAT R30 MUST BE INSTALLED IN CEILING |
| | ATTIC AND BLOCK WALL REQUIRE A MINIMUM R7*********** |
| | |
| | 11)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED |
| | |
| | |
| | NEW COMMENTS: |
| | |
| | 1)IF WINDOWS AND DOORS THAT ARE BEING INSTALLED IN |
| | THE NEW ADDITION ARE NOT IMPACT RESISTANT PLEASE SUBMIT |
| | PRODUCT APPROVALS AND INSTALLATION SCHEDULE FOR |
| | PROTECTIVE DEVICES. SEE ATTACHED CITY MEMO AND |
| | SCHEDULE |
| | |
| | 2)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS |
| | OF NEW DRAWINGS WITH REVISIONS AND INCLUDE 1 COPY OF |
| | THE OLD PAGES ONLY FOR REFERENCE. PLEASE ASSEMBLE ALL |
| | SIGNED AN SEALED DRAWINGS THAT PERTAIN TO WORK BEING |
| | PERFORMED, TOGETHER IN COMPLETE SETS AND SUBMIT WITH |
| | ONLY 1 SET OF REFERENCE DRAWINGS. PLEASE SUBMIT |
| | REQUIRED DOCUMENTS FOR ALL OTHER REVIEWERS |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |