| Date |
Text |
| 2007-09-17 12:51:41 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | |
| | 1. APPLICATION INDICATESREPAIR OF BACK PORCH, BUT |
| | PLANS INDICATE ADDITION. PLEASE CORRELATE APPLICATION, |
| | WHICH REQUIRES DESCRIPTION OF PROJECT IN DETAIL,AND |
| | PLANS. SECTION 105.1. |
| | |
| | 2. SHT A1 AREA CALCULATIONS INDICATES NEW LIVING AREA |
| | 251SF TO BE NEW BEDROOMS, BUT THE FLOOR PLAN SHOWS NEW |
| | FAMILY ROOM AND NEW LAUNDRY ROOM. PLEASE CORRELATE |
| | INFORMATION. SECTION 106.1.1. |
| | |
| | 3. SHT A1 SANITARY RISER DIAGRAM. SHOW ALL PIPE SIZES. |
| | THE MINIMUM TRAP SIZE FOR A WASH MACHINE IS 2" PER |
| | TABLE 709.1, BUT RISER SHOWS 1-1/2" WASTE ARM TO THE |
| | TRAP. MINIMUM 2" WASTE ARM TO TRAP REQUIRED.--THE |
| | STACK SHALL BE A MINIMUM 3" UP TO THE SANITARY TEE PER |
| | SECTION 406.3. PLEASE INDICATED STACK SIZE.--THE |
| | WASH MACHINE REQUIRES A STANDPIPE MINIMUM 18" UPSTREAM |
| | OF THE TRAP. PLEASE SHOW ON RISER. SECTIONS 802.4 & |
| | 1002.1.--A CLEANOUT IS REQUIRED ON THE STACK. THE |
| | CLEANOUT, IF TO THE OUTSIDE, CAN BE LOW AT THE BASE OF |
| | THE STACK. IF TO THE INSIDE SHALL BE SHOWN MINIMUM 4' |
| | ABOVE THE FLOOR FOR ACCESS. SECTIONS 708.3.4 & 708.9. |
| | INDICATE CLEANOUT ON RISER. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID |
| | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY |
| | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU |
| | FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |