| 2007-10-22 14:47:42 | 1. DUCTWORK APPEARS TO PASS THROUGH STAIR # 1 ON PAGE |
| | M1.02. PLEASE PROVIDE DETAILS, MECHANICAL EQUIPMENT IS |
| | NOT ALLOWED TO PASS THROUGH A REQUIRED EXIT STAIR. |
| | |
| | 2. FUTURE TENANT SEPARATIONS WILL BE REQUIRED WHEN THE |
| | FUTURE SPACES ARE LEASED. |
| | |
| | 3. BUILDING ADDRESS REQUIRED ON PROPER ELEVATION. A |
| | MINIMUM OF AT LEAST 6" HIGH NUMBERS AND AT LEAST 1" |
| | WIDE SHALL BE PROVIDED. NUMBERS SHOULD CONTRAST WITH |
| | THE BACKGROUND THEY ARE MOUNTED ON. |
| | |
| | 4. WHAT PROTECTION IS BEING AFFORDED TO EXITING FROM |
| | STAIR # 1 AND TO EXITING OCCURING FROM THE EXTERIOR |
| | STAIRS. IT APPEARS THAT DOORS IN THE LOBBY ARE NOT FIRE |
| | RATED AND WINDOWS APPEAR TO BE WITHIN CLOSE PROXIMITY |
| | TO THE EXTERIOR STAIR. THERE APPEARS TO BE NO |
| | PROTECTION TO PROVIDE FOR EXITING. |
| | |
| | 5. PLEASE PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENTS |
| | FOR ALL HANDRAILS AND GUARDRAILS. |
| | |
| | 6. WHAT SLIP RESISTANT METHODS ARE PLANNED FOR THE |
| | EXTERIOR FIRE STAIR. |
| | |
| | 7. ELEVATOR WARNING SIGNS REQUIRED AT ELEVATOR |
| | OPENINGS. |
| | |
| | 8. ELEVATOR INSTALLATION TO COMPLY WITH ANSI A17.1. |
| | |
| | 9. TACTILE SIGNAGE REQUIRED AT EXIT DOOR LOCATIONS. |
| | |
| | 10. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY |
| | WITH NFPA 241. |
| | |
| | 11. DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. |
| | |
| | 12. PLEASE INDICATE INTERIOR FINISH CLASSIFICATIONS FOR |
| | WALLS AND CEILINGS. |
| | |
| | 13. PLEASE ILLUSTRATE PORTABLE FIRE EXTINGUISHER |
| | LOCATIONS. |
| | |
| | |
| | MIKE CARSILLO, BATTALION CHIEF |
| | 804-4709 PHONE |
| | 804-4774 FAX |