Plan Review Notes
Plan Review Notes For Permit 07080952
Permit Number 07080952
Review Stop B
Sequence Number 2
Notes
Date Text
2007-12-18 13:30:12BUILDING PLAN REVIEW
 PERMIT: 07080952
 ADD: 310 FLAMINGO DRIVE
 CONT: ISLAND CONSTRUCTION
 TEL: (561)236-9983
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1A)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 1B)PLEASE SUBMIT 2 OF ALL SURVEYS, PLANS, REPORTS,
 REVISIONS , PRODUCT APPROVALS AND OR SUBMITTALS FOR
 REVIEW FOR PERMIT.
 IF YOUR PROJECT WILL REQUIRE A RESIDENT INSPECTOR OR IF
 YOUR PROJECT IS A THRESHOLD BUILDING REQUIRING A
 THRESHOLD INSPECTOR THEN (3) THREE SETS OF ALL SAID
 DOCUMENTS WILL BE REQUIRED FOR PERMIT ISSUANCE. 106.1*
 /2004 SUBMITTAL DOCUMENTSWEST PALM BEACH
 ADMINISTRATIVE CODE.
  
 1C) 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "SHALL NOT BE CITED AS
 A WHOLE OR IN PART, NOR THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 1D ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 2-3) COMPLIED.
  
 4) PARTIALLY COMPLIED. PLANS DO INDICATE A LEVEL II
 ALTERATION, THE APPLICABLE CODES ARE 2004 FBC WITH 2007
 REVISIONS ORSUPPLEMENTS 2004 EXISTING BUILDING CODE,
 AND THE 2004 RESIDENTIAL CODE WITH 2007 REVISIONS OR
 SUPPLEMENTS.
 THE PLANS CURRENTLY INDICATE THIS TO BE A R3 RESIDENCE
 AND THE GARAGE A ACCESSORY USEAGE. THE PLANS DO MEET
 THIS CRITERIA FOR A ONE & TWO FAMILY RESIDENCE AND THIS
 REVIEW WILL BE COMPLETED AS SUCH.
 FOR THE BUILDING DEPARTMENTS OCCUPANCY CLASSIFICATION
 IT WILL NEED TO REPRESENT A R3 OCCUPANCY ON THE SHEET
 A.0. WE HAVE NO SUCH CLASSIFICATION AS COMMERCIAL LIVE/
 WORKIF THIS IS A ZONING CLASSIFICATION PLEASE SESIGNATE
 AS SUCH.
  
 5) SEMI-COMPLIED, THE RESPONCE INDICATES AS WELL AS THE
 PLANS THIS IS TO BE A R3 RESIDENCE AND THE RESPONCE
 LETTER INDICATES THE STORAGE PORTION TO BE USED AS A
 GARAGE.WITH THIS NEW KNOWLEDGE OF WHAT TYPE OF
 OCCUPANCY CLASSIFICATION WILL BE USED FOR THIS
 STRUCTURE THE DESIGNER NEEDS TO COMPLY WITH R 309.1
 OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM
 USED FOR SLEEPING SHALL NOT BE PERMITTED. SEE THE REST
 OF THE SECTION AS TO FIRE RATINGS REQUIRED.
  
 6-11) COMPLIED.
  
 12-13) BOTH COMMENTS DEAL WITH THE ENERGY CALCS, THE
 ENERGY CALCULATIONS ARE COMPLETED ON FORM 400A, THIS
 PLAN NOW STATES THIS IS A R-3 OCCUPANCY WITH THE GARAGE
 BEING A ACCESSORY OCCUPANCY, THERE ARE NO LONGER WALLS
 WITH SEPERATION BETWEEN BAYS. PLEASE REVISE THE ENERGY
 CALCULATIONS. NOTE THE ENERGY CALCULATIONS NEED TO
 ACCURATELY DEPICT THE FIXTURES LISTED ON SHEET E-2.
  
 14) THIS PLAN APPEARS TO HAVE A CHANGE IN OCCUPANCY
 REQUIRING PALM BEACH COUNTY IMPACT FEE ASSESSMENT.
 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS
 OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF
 CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST
 RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT
 BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC
 REQUIREMENT, THE SPECIFIC
 REQUIREMENT SHALL BE APPLICABLE.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved