| Date |
Text |
| 2007-12-15 09:31:53 | |
| | |
| | DENIED |
| | THE FOLLOWING COMMENTS WERE NOT ADDRESSED ON THE 1ST |
| | REVIEW: |
| | |
| | 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | *******ADJUSTED VALUE FOR REMODELLED FIRST FLOOR AREA, |
| | VALUE STILL EXCEEDS AMOUNT STATED ON PERMIT |
| | APPLICATION****** |
| | |
| | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | *******THESE FEES ARE BASED ON NEW UNDER ROOF SQUARE |
| | FOOTAGE****** |
| | |
| | NOTE: FEES ARE DUE IN THE AMOUNT OF $773.37FOR |
| | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW |
| | |
| | 5)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING |
| | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF |
| | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND |
| | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE |
| | DRAWINGS |
| | |
| | 6)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 |
| | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER |
| | AND OWNER/AGENT PRIOR |
| | TO SUBMITTAL ********ENERGY CALC'S NOT CORRECT, |
| | DRAWINGS SHOW ATTIC INSULATION AS R30 AND CALC'S ARE |
| | R19, NO DESIGNATION FOR BLOCK WALLS AND WOOD FRAME |
| | WALLS ON SECOND FLOOR WAS MADE******* |
| | |
| | 11)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE |
| | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES. |
| | ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG |
| | |
| | 12)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | *******ALL PRODUCT APPROVALS/SHOP DRAWINGS, ETC ARE |
| | REQUIRED TO BE REVIEWED AND APPROVED BY PERSONS |
| | RESPONSIBLE FOR DRAWINGS******** |
| | |
| | 13)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| | STATE PRODUCT APPROVAL COVER |
| | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON |
| | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT |
| | SUBMITTED APPLICATIONS WILL BE DENIED. |
| | |
| | NEW REVIEW COMMENTS |
| | |
| | 1)PROVIDE INFORMATION ON THE DRAWINGS FOR NEW ROOM |
| | ADDED TO ROOF DECK, DOES THIS COVER ROOF ACCESS HATCH? |
| | NO PLAN VIEW, STRUCTURAL ATTACHMENT METHOD, DOOR OR |
| | WINDOWS NOT IN SCHEDULES, ETC. |
| | |
| | 2)PROVIDE ATTACHMENT METHOD FOR BILKO ROOF HATCH, |
| | SHOP DRAWING DOES NOT SPECIFY |
| | |
| | 3) PROVIDE NOTE ON THE DRAWINGS FOR BUILDING |
| | PAPER/WATERPROOFING PER THE HARDIPLANK PRODUCT |
| | APPROVAL |
| | |
| | 4)ELEVATIONS DEPICT A LOWER ROOF HEIGHT WITH NEW |
| | ALUMINUM RAILINGS, THESE CHANGES ARE NOT REFLECTED ON |
| | THE BUILDING SECTIONS OR DETAILS |
| | |
| | 5)PROVIDE ATTACHMENT METHOD FOR RAILING SYSTEM AT |
| | ROOF AND BALCONY, NOA IS FOR EMBEDMENT INTO CONCRETE |
| | BLOCK/TIE BEAM |
| | |
| | 6)CHOOSE SYSTEM THAT WILL BE USED FROM FLAT ROOF NOA, |
| | BE SURE THAT IT WILL MEET THE REQUIRED DESIGN PRESSURE |
| | FROM SHEET A-12 FOR THE PERIMETER AND CORNER ZONES OR |
| | PROVIDE ENHANCED FASTENING REQUIREMENTS AS OUTLINED IN |
| | LIMITATION #7 AT END OF NOA. PLEASE NOTE THAT THIS |
| | MIAMI-DADE REPORT HAS BEEN REVISED AND RENEWED BY |
| | REPORT #07-0228.06 |
| | |
| | 7)PLEASE CLARIFY TYPE OF DOOR ON WEST ELEVATION, PLAN |
| | STATES FRENCH DOOR BUT SCHEDULE SHOWS PANEL DOOR, IF |
| | DOOR IS METAL PANEL PROVIDE PRODUCT APPROVAL |
| | |
| | 8)PER 713.13(2) F.S. |
| | IF THE IMPROVEMENT DESCRIBED IN THE NOC HAS NOT |
| | COMMENCED WITHIN 90 DAYS OF RECORDING, THE NOTICE IS |
| | VOID |
| | |
| | |
| | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 |
| | AMENDMENTS |
| | FBC* = WEST PALM BEACH ADMINISTRATIVE |
| | AMENDMENTS TO FBC |
| | FAC = FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | FBC RES. = FLORIDA BUILDING CODE |
| | RESIDENTIAL 2004 W/2006 AMENDMENTS |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |