Plan Review Notes
Plan Review Notes For Permit 07080811
Permit Number 07080811
Review Stop B
Sequence Number 1
Notes
Date Text
2007-09-11 16:56:13COMMERCIAL AWNINGS BUILDING REVIEW FIRST CHECKLIST.
 REVIEW DONE UNDER FBC 2004 WITH 2007 REVISIONS.
  
 1- INSTALLATION OF AWNINGS IS OUT OF THE SCOPE OF WORK
 CONTRACTOR'S LICENSE ES12000166. THIS LICENSE IS TO
 INSTALL SIGNS, NOT AWNINGS.CONTRACTOR WHO CAN
 INSTALLAWNINGS NEEDSTO APPLY FOR THE PERMIT.
  
 2- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO LOW.
 IN ADDITION, ENGINEERING FEES SHALL BE INCLUDED.
 UPDATE VALUE OR IT WILL BE ESTIMATED AS REQUIRED BY
 SEC. 108.3 CITY AMENDMENTS TO FBC 2004.
  
 3- FABRIC USED SHALL BE FLAME RESISTANT AS REQUIRED BY
 SEC. 3105.3.1FBC 2004. PROVIDE COMPLETE
 SPECIFICATIONS TO SHOW COMPLIANCE WITH THIS SECTION.
  
 4- ENGINEER TO CLEARLY INDICATE WHICH DESIGN CRITERIA
 WAS USED FOR THE FRAMING AND FABRIC AS REQUIRED BY SEC.
 3105.4.2 FBC 2004.IF DESIGNING WITH FABRIC TO BE
 REMOVED WITH A QUICK REMOVAL OR BREAKAWAYMEMBRANE,
 THEN COMPLETE SERIES OF PICTURES IS REQUIRED TO BE
 SUBMITTED FOR BUILDING OFFICIAL APPROVAL.
  
 5- PROVIDE COMPLETE DIMENSIONS FOR INTERIOR TRUSSES.
 AWNING FRAME SECTION DETAIL SHOWN CALLS FOR "TO BE
 DET".NEED TO PROVIDE COMPLETE DIMENSIONS. THIS IS
 PART OF THE ENGINEERING DESIGN. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712