| 2008-04-09 12:16:09 | BUILDING PLAN REVIEW |
| | PERMIT: 07080709 |
| | ADD: 101 EXECUTIVE CENTER DR. |
| | CONT: KAY RESTORATION CORP. |
| | TEL: (561)994-9300 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)THE ALTERATION LEVEL 1 STATED ON SHEET 3/3 IS |
| | INCORRECT. FBC (EXISTING) SEC. 304 ANY RECONFIGURATION |
| | OF SPACE, THE ADDITION OR ELIMINATION OF ANY DOOR OR |
| | WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, |
| | OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT IS A |
| | LEVEL 2 ALTERATION. THE CHANGES SHOWN ON THE PLANS |
| | INDICATE THIS PROJECT AS A LEVEL 2 NOT LEVEL 1 AS |
| | STATED ON THE PLANS. |
| | |
| | 3)FBC 106.1.1* CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND SHALL BE OF SUFFICIENT CLARITY TO |
| | INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | FBC 2004 CODE AND RELEVANT LAWS. THERE ARE NO |
| | DIMENSIONS ON THE DRAWINGS. |
| | |
| | 4)110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD KEEPING: |
| | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT IS |
| | DESIGNED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| | PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, |
| | TABLE 601. |
| | D) THE OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED |
| | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| | BUILDING PERMIT |
| | ) NUMBER OF UNITS |
| | ) NUMBER OF FLOORS |
| | ) NUMBER OF ROOMS |
| | ) SQ. FT. FOOTPRINT |
| | THE ENTIRE FLOOR PLAN SHALL BE SUBMITTED ON THE |
| | DRAWINGS NOT A PARTIAL FLOOR PLAN. |
| | |
| | 5)FBC 11-4.17.2 WATER CLOSETS IN ACCESSIBLE STALLS |
| | SHALL COMPLY WITH SECTION 11-4.16.AND FIG 30E. SHOW |
| | THE CLEAR FLOOR SPACE, OF THE WATER CLOSEST, THE FLUSH |
| | CONTROLS AND TOILET PAPER DISPENSERS. |
| | |
| | 6)A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS |
| | A RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | 7)A WALL DETAIL SHALL BE SUBMITTED INDICATING WHAT |
| | MATERIALS WILL BE USED TO CONSTRUCT THE NEW WALLS. |
| | SUBMIT A WALL LEGEND SHOW THE DIFFERENT TYPE OF WALL. |
| | |
| | 8)FBC SEC.803 INDICATE THE TYPE OF FINISH IN |
| | ACCORDANCE WITH TABLE 803.5 |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |
| | |
| | %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% |
| | |
| | BUILDING PLAN REVIEW #2 |
| | PERMIT: 07080709 |
| | ADD: 101 EXECUTIVE CENTER DR. |
| | CONT: KAY RESTORATION CORP. |
| | TEL: (561)994-9300 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 2ND |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)OK |
| | 3)OK |
| | |
| | 4)110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD KEEPING: |
| | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT IS |
| | DESIGNED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| | PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, |
| | TABLE 601. |
| | D) THE OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED |
| | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| | BUILDING PERMIT |
| | ) NUMBER OF UNITS |
| | ) NUMBER OF FLOORS |
| | ) NUMBER OF ROOMS |
| | ) SQ. FT. FOOTPRINT |
| | THE ENTIRE FLOOR PLAN SHALL BE SUBMITTED ON THE |
| | DRAWINGS NOT A PARTIAL FLOOR PLAN. |
| | IS THIS A STAND ALONE BUILDING, OR IS IT CONNECTED TO |
| | ANOTHER? |
| | |
| | 5)FBC 11-4.17.2 WATER CLOSETS IN ACCESSIBLE STALLS |
| | SHALL COMPLY WITH SECTION 11-4.16.AND FIG 30E. SHOW |
| | THE CLEAR FLOOR SPACE, OF THE WATER CLOSEST, THE FLUSH |
| | CONTROLS AND TOILET PAPER DISPENSERS. |
| | |
| | 6)A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS |
| | A RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | 7)A WALL DETAIL SHALL BE SUBMITTED INDICATING WHAT |
| | MATERIALS WILL BE USED TO CONSTRUCT THE NEW WALLS. |
| | SUBMIT A WALL LEGEND SHOW THE DIFFERENT TYPE OF WALL. |
| | |
| | 8)FBC SEC.803 INDICATE THE TYPE OF FINISH IN |
| | ACCORDANCE WITH TABLE 803.5 |
| | |
| | **NEW** |
| | 9)FBC 1210.2 WALLS WITHIN 2 FEET OF URINALS AND WATER |
| | CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT |
| | SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FINISH FLOOR. |
| | NOTE: PAINT ON DRYWALL IN NOT CONSIDERED A HARD |
| | SURFACE.SHOW COMPLIANCE. |
| | |
| | 10)61G15-23.002 A TITLE BLOCK SHALL BE USED ON EACH |
| | SHEET CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE |
| | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND |
| | LICENSE NUMBER OF THE ENGINEER, AND IF PRACTICING |
| | THROUGH A DULY AUTHORIZED ENGINEERING BUSINESS, THE |
| | NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER |
| | OF THE ENGINEERING BUSINESS. |
| | |