| Date |
Text |
| 2007-09-17 19:41:16 | GREAT WRAPS RESTARAUNT |
| | 2409 S DIXIE HWY |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07080695 |
| | ADD: 2409 S DIXIE HWY |
| | CONT: L DAVIS CONSTRUCTION |
| | TEL: (561)718-8161 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE |
| | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT |
| | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE |
| | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE SHOWN ON THE |
| | CONSTRUCTION DRAWINGS, |
| | 1)- BASIC WIND SPEED, MPH |
| | 2)- WIND IMPORTANCE FACTOR, & BUILDING CATEGORY 3)- |
| | WIND EXPOSURE |
| | 4)- INTERNAL PRESSURE COEFFICIENT, |
| | 5)- COMPONENTS & CLADDING, THE DESIGN WIND PRESSURES IN |
| | TERMS OF PSF. |
| | |
| | 4) 106.1.2* ADDITIONAL INFORMATION. PLANS INDICATE WHAT |
| | APPEARS TO BE A CONCRETE RAMP THAT TRANSFERS IN TO A |
| | WOOD RAMP, PLEASE PROVIDE A CUT SECTION FOR THE FULL |
| | LENGTH OF THE RAMP WHAT IS DRAWN ISN'T CLEAR. THE SITE |
| | PLAN INDICATES THE BOTTOM OF THE RAMP LOCATED AT THE |
| | TRAFFIC LANE OF THE PARKING LOT ,NO BOTTOM LANDING. |
| | PLEASE PROVIDE TOP AND BOTTOM LANDINGS.11-4.8.4.(2) |
| | LANDINGS. ALL LANDINGS ON RAMPS SHALL NOT BE LESS THAN |
| | 60" CLEAR, & THE BOTTOM OF EACH RAMP SHALL HAVE NOT |
| | LESS THAN 72" OF STRAIGHT & LEVEL CLEARENCE. 11-4.8.3. |
| | CLEAR WIDTH. THE MINIMUM CLEAR WIDTH OF A RAMP SHALL BE |
| | 36". EXCEPTION: RAMPS THAT ARE PART OF A REQUIRED MEANS |
| | OF EGRESS SHALL NOT BELESS THAN 44 INCHES WIDE. |
| | |
| | 5) PLEASE PROVIDE CUT SECTION OF THE NEW OUTSIDE DECK, |
| | PLEASE INDICATE GRADE, ELEVATION ABOVE GRADE, FRMING |
| | MATERIALS, SIZE, SPECIES OF WOOD, FREQUENCY OF FRAMING |
| | MEMBERS,AND DECKING MATERIALS. 106.1.2* ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 6) 11-4.33.2 SIZE OF WHEELCHAIR LOCATIONS. |
| | EACH WHEELCHAIR LOCATION SHALL PROVIDE MINIMUM CLEAR |
| | GROUND OR FLOOR SPACES AS SHOWN IN FIGURE 46 . |
| | |
| | 11-4.33.3 PLACEMENT OF WHEELCHAIR LOCATIONS. WHEELCHAIR |
| | AREAS SHALL BE AN INTEGRAL PART OF ANY FIXED SEATING |
| | PLAN AND SHALL BE PROVIDED SO AS TO PROVIDE PEOPLE WITH |
| | PHYSICAL DISABILITIES A CHOICE OF ADMISSION PRICES AND |
| | LINES OF SIGHT COMPARABLE TO THOSE FOR MEMBERS OF THE |
| | GENERAL PUBLIC. THEY SHALL ADJOIN AN ACCESSIBLE ROUTE |
| | THAT ALSO SERVES AS A MEANS OF EGRESS IN CASE OF |
| | EMERGENCY. AT LEAST ONE COMPANION FIXED SEAT SHALL BE |
| | PROVIDED NEXT TO EACH WHEELCHAIR SEATING AREA. |
| | 11-5.3 ACCESS AISLES. |
| | ALL ACCESSIBLE FIXED TABLES SHALL BE ACCESSIBLE BY |
| | MEANS OF AN ACCESS AISLE AT LEAST 36 INCHES (915 MM) |
| | CLEAR BETWEEN PARALLEL EDGES OF TABLES OR BETWEEN A |
| | WALL AND THE TABLE EDGES. |
| | |
| | 11-5.4 DINING AREAS. |
| | IN NEW CONSTRUCTION, ALL DINING AREAS, INCLUDING RAISED |
| | OR SUNKEN DINING AREAS, LOGGIAS, AND OUTDOOR SEATING |
| | AREAS, SHALL BE ACCESSIBLE. IN ALTERATIONS, |
| | ACCESSIBILITY TO RAISED OR SUNKEN DINING AREAS, OR TO |
| | ALL PARTS OF OUTDOOR SEATING AREAS IS NOT REQUIRED |
| | PROVIDED THAT THE SAME SERVICES AND DECOR ARE PROVIDED |
| | IN AN ACCESSIBLE SPACE USABLE BY THE GENERAL PUBLIC AND |
| | ARE NOT RESTRICTED TO USE BY PEOPLE WITH DISABILITIES. |
| | |
| | |
| | 7A) SHEET A-1 INDICATES A NEW EXTERIOR DOOR, IS THIS A |
| | NEW DOORWAY OR A NEW DOOR AND FRAME? IF A NEW DOORWAY |
| | PROVIDE DETAILS OF REINFORCEMENT AROUND THE OPENING FOR |
| | EITHER BLOCK OR WOOD FRAME. THE NEW DOOR ASSEMBLY WILL |
| | REQUIRE PRODUCT APPROVAL PLEASE SUBMIT 2 COPIES. |
| | |
| | 7B) PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION |
| | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE |
| | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE |
| | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. |
| | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT |
| | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT |
| | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR |
| | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE |
| | 9B-72. |
| | |
| | 7C)WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 8)SHEET A-1 INDICATES A NEW WALL AND DOOR PLEASE |
| | PROVIDE MATERIALS THE NEW WALL IS MADE OF AND SIZE OF |
| | DOOR. 106.1.2* ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 9) THERE IS ONLY ONE SET OF PLANS PLEASE SUBMIT TWO |
| | SETS OF PLANS FOR THE NEXT REVIEW. |
| | |
| | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS |
| | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF |
| | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST |
| | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT |
| | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC |
| | REQUIREMENT, THE SPECIFIC |
| | REQUIREMENT SHALL BE APPLICABLE. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | |
| | |
| | |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |