| 2007-11-21 18:58:33 | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07080580 |
| | ADD: 518 21ST STREET |
| | CONT: WPB HOUSING AUTHORITY |
| | TEL: (561)655-8530 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2007 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 2ND |
| | ACTION: DENIED |
| | |
| | 1A)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) 106.3.3* PRODUCT APPROVALS- 2004 |
| | THOSE PRODUCTS THAT ARE REGULATED BY DCA RULE 9B-72 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. THE PRODUCT APPROVALS FOR THE |
| | ?DOORS, WINDOWS AND MULLIONS? ARE MISSING FROM THE |
| | PACKAGE. |
| | |
| | 3) ON SHEET A-6, INDICATE WHAT MATERIAL WILL BE USED ON |
| | THE WALLS AROUND THE BATHTUBS WHEN THE EXISTING |
| | MATERIAL IS REMOVED. STATE IF DUROCK, GREEN BOARD OR |
| | DENSE GLASS ETC. WILL BE USED. CLARIFY PER 106.1.2 |
| | |
| | 4)INTERIOR WALL AND CEILING FINISH SHALL HAVE A FLAME |
| | SPREAD INDEX NOT GREATER THAN THAT SPECIFIED IN TABLE |
| | 803.5. INDICATE ON THE PLANS THE FLAME SPREAD IN |
| | ACCORDANCE WITH FBC SECTION 803. |
| | |
| | MYRON JACOBS |