| Date |
Text |
| 2008-01-17 11:41:10 | 2004 FBC W/2007 SUPPLEMENTS |
| | NSFR |
| | |
| | DENIED BY BUILDING |
| | |
| | 1) COMPLIED |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT |
| | MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. WORK MUST COMMENCE WITHIN 90 DAYS |
| | OF THE DATE THE NOC IS RECORDED. FS 713.13. THE ONE |
| | THAT WAS SUBMITTED IS EXPIRED. |
| | |
| | 3) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. SUBMIT COPY OF |
| | THE PAID RECEIPT FOR THE IMPACT FEES. |
| | |
| | 4) COMPLIED |
| | |
| | 5)COMPLIED |
| | |
| | 6) COMPLIED |
| | |
| | 7) COMPLIED |
| | |
| | 8) COMPLIED |
| | |
| | 9)NOTE THAT THE DEFINITION FOR EXPOSURE C HAS CHANGED |
| | EFFECTIVE DECEMBER 8, 2006 (2006 AMENDMENTS TO THE |
| | FBC), FBC1609.4, FBC R301.2.1.4. |
| | EXPOSURE C. OPEN TERRAIN WITH SCATTERED |
| | OBSTRUCTIONS, INCLUDING SURFACE UNDULATIONS OR OTHER |
| | IRREGULARITIES, HAVING HEIGHTS GENERALLY LESS THAN 30 |
| | FEET (9144 MM) EXTENDING MORE THAN 1,500 FEET (457.2 M) |
| | FROM THE BUILDING SITE IN ANY QUADRANT. THIS EXPOSURE |
| | SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN |
| | EXPOSURE B-TYPE TERRAIN WHERE THE BUILDING IS DIRECTLY |
| | ADJACENT TO OPEN AREAS OF EXPOSURE C-TYPE TERRAIN IN |
| | ANY QUADRANT FOR A DISTANCE OF MORE THAN 600 FEET |
| | (182.9 M). THE STRUCTURE IS LOCATED ADJACENT TO A GOLF |
| | COURSE WHICH MAY REQUIRE IT TO BE DESIGNED AS EXPOSURE |
| | C. PLEASE REVISE PLANS OR INDICATE WHY THE EXPOSURE |
| | CATEGORY SHOULD NOT BE CHANGED. ADDITIONAL COMMENTS: |
| | THE INFORMATION THAT WAS SUBMITTED DOES NOT CONSIDER |
| | THE TERRAIN IN THE ENTIRE REAR QUADRANT, WHICH INCLUDES |
| | THE TERRAIN FOR 45 DEGREES EITHER SIDE OF THE WIND |
| | DIRECTION BEING CONSIDERED. SEE ASCE 7-02 SECTION |
| | 6.5.6.1. ALSO SEE ATTACHED COPIES OF THE 2004 FBC |
| | RESIDENTIAL CODE COMMENTARY AND ASCE 7-02. |
| | |
| | 10) COMPLIED |
| | |
| | 11) COMPLIED |
| | |
| | 12) COMPLIED |
| | |
| | 13) COMPLIED |
| | |
| | 14) COMPLIED |
| | |
| | 15) COMPLIED |
| | |
| | 16) COMPLIED |
| | |
| | 17)COMPLIED |
| | |
| | 18) COMPLIED |
| | |
| | 19) COMPLIED |
| | |
| | 20) COMPLIED |
| | |
| | 21) COMPLIED |
| | |
| | 22)COMPLIED |
| | |
| | 23) COMPLIED |
| | |
| | 24) COMPLIED |
| | |
| | 25) REVISE COMPONENT AND CLADDING PRESSURES TO EXPOSURE |
| | CATEGORY 'C'. SEE ITEM #9. |
| | |
| | 26) COMPLIED |
| | |
| | 27) COMPLIED |
| | |
| | 28) COMPLIED |
| | |
| | 29) COMPLIED |
| | |
| | 30) N/A |
| | |
| | 31) COMPLIED |
| | |
| | 32) COMPLIED |
| | |
| | 33) COMPLIED |
| | |
| | 34) CORRECTED |
| | |
| | 35) COMPLIED |
| | |
| | 36) COMPLIED |
| | |
| | 37) COMPLIED |
| | |
| | 38) COMPLIED |
| | |
| | 39) CORRECTED |
| | |
| | 40) COMPLIED |
| | |
| | 41) COMPLIED |
| | |
| | 42)COMPLIED |
| | |
| | 43)COMPLIED |
| | |
| | 44) COMPLIED |
| | |
| | 45) CORRECTED |
| | |
| | 46) COMPLIED |
| | |
| | 47)COMPLIED |
| | |
| | 48) COMPLIED |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)805-6714 |
| | [email protected] |
| | |