Plan Review Notes
Plan Review Notes For Permit 07080572
Permit Number 07080572
Review Stop B
Sequence Number 1
Notes
Date Text
2007-09-17 17:26:362004 FBC W/2007 SUPPLEMENTS
 NSFR
  
 DENIED BY BUILDING
  
 1) UNITY OF TITLE FOR THE LOTS MUST BE COMPLETED AND
 ADDRESS ASSIGNED BEFORE PERMIT IS ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 4)THE PLANS SPECIFY TYPE III UNPROTECTED
 CONSTRUCTION, WHICH UNDER THE 2004 CODE IS TYPE III-B.
 PLEASE SPECIFY A OR BE ON THE PLANS. SEE FBC CHAPTER 6.
 NOTE: TYPE III CONSTRUCTION REQUIRES EXTERIOR WALLS TO
 HAVE A TWO HOUR FIRE RATING IN ADDITION TO OTHER
 REQUIREMENTS. SEE TABLES 601 AND 602. NOTE: THIS
 STRUCTURE COULD BE DECLARED TYPE V-B CONSTRUCTIONAND
 IT WOULD STILL COMPLY WITH THE HEIGHT AND AREA
 REQUIREMENTS OF TABLE 503. TYPE V-B CONSTRUCTION DOES
 NOT REQUIRE THE EXTERIOR WALLS TO BE FIRE RATED. IF YOU
 ARE SPECIFYING TYPE III CONSTRUCTION SUBMIT
 CALCULATIONS AS TO HOW THE 2 HOUR FIRE RATING WILL BE
 OBTAINED. SUBMIT A LETTER FROM THE CONCRETE BLOCK
 SUPPLIER THAT SPECIES THE THICKNESS AND AGGREGATE IN
 THE BLOCK AND THE FIRE RESISTANCE RATING IN HOURS.
  
 5)FBC R401.4AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL. SUBMIT 2 SIGNED AND SEALED COPIES.
  
 6) THE PLANS ARE REQUIRED TO HAVE THE ORIGINAL
 SIGNATURE OF THE ENGINEER AND ARCHITECT IN ADDITION TO
 THE LICENSE NUMBERS OF THE ENGINEERING AND
 ARCHITECTURAL FIRMS. SEE FS 471 AND 481. SEE THE
 ELECTRICAL REVIEW COMMENTS.
  
 7) THE FLOOD ZONE DESIGNATION ON THE SURVEY IS
 SPECIFIED AS A8, WHICH IS INCORRECT. THIS AREA IS
 INCLUDED IN THE LETTER OF MAP REVISION (LOMR) FOR THE
 VILLAGES OF PALM BEACH LAKES AND SPENCER LAKES PLATS
 1,2 AND 3 DATED DECEMBER 3, 1983. PLEASE CORRECT.
  
 8) THE ENERGY CALCULATIONS LISTS THE CONDITIONED FLOOR
 AREA AS 8000 SQFT AND THE PLANS SPECIFY 8327 SQFT.
 PLEASE CORRECT.
  
 9)NOTE THAT THE DEFINITION FOR EXPOSURE C HAS CHANGED
 EFFECTIVE DECEMBER 8, 2006 (2006 AMENDMENTS TO THE
 FBC), FBC1609.4, FBC R301.2.1.4.
 EXPOSURE C. OPEN TERRAIN WITH SCATTERED
 OBSTRUCTIONS, INCLUDING SURFACE UNDULATIONS OR OTHER
 IRREGULARITIES, HAVING HEIGHTS GENERALLY LESS THAN 30
 FEET (9144 MM) EXTENDING MORE THAN 1,500 FEET (457.2 M)
 FROM THE BUILDING SITE IN ANY QUADRANT. THIS EXPOSURE
 SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN
 EXPOSURE B-TYPE TERRAIN WHERE THE BUILDING IS DIRECTLY
 ADJACENT TO OPEN AREAS OF EXPOSURE C-TYPE TERRAIN IN
 ANY QUADRANT FOR A DISTANCE OF MORE THAN 600 FEET
 (182.9 M). THE STRUCTURE IS LOCATED ADJACENT TO A GOLF
 COURSE WHICH MAY REQUIRE IT TO BE DESIGNED AS EXPOSURE
 C. PLEASE REVISE PLANS OR INDICATE WHY THE EXPOSURE
 CATEGORY SHOULD NOT BE CHANGED.
  
 10) THE WALLS OF THE WINE ROOM ARE REQUIRED TO BE
 WATERPROOFED IN ACCORDANCE WITH FBC R406.
  
 11) PROVIDE DETAILS OF THE MASONRY FIREPLACES AND
 CHIMNEYS IN THE LIVING ROOM AND AT THE COVERED PATIO.
 SEE SECTIONS R1001 AND R1003. COORDINATE WITH THE
 STRUCTURAL ENGINEER FOR THE FOUNDATION REQUIREMENTS.
 SPECIFY REINFORCING, ETC.
  
 12) PROVIDE DETAILS FOR THE PRE-FAB FIREPLACE AND
 CHIMNEY. SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND
 LISTING INFORMATION FOR THE FIREPLACE AND CHIMNEY.
  
 13) PROVIDE DETAILS FOR THE CHIMNEY CAPS. SPECIFY
 MATERIALS, ATTACHMENTS, FASTENERS, ETC.
  
 14) PROVIDE STRUCTURAL DETAILS FOR THE WOOD FRAME FAKE
 CHIMNEY. SPECIFY MATERIALS, CONNECTIONS, ETC.
  
 15) AT INTERIOR STAIRS AND SECOND FLOOR LANDING SHOW
 COMPLIANCE WITH R312.2 GUARD OPENING LIMITATIONS.
 REQUIRED GUARDS ON OPEN SIDES OF STAIRWAYS, RAISED
 FLOOR AREAS, BALCONIES AND PORCHES SHALL HAVE
 INTERMEDIATE RAILS OR ORNAMENTAL CLOSURES WHICH DO NOT
 ALLOW PASSAGE OF A SPHERE 4 INCHES (102MM) OR MORE IN
 DIAMETER.
  
 16) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS .
 IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF
 CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED
 TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 )
 AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR
 GREATER. THE ROUGH-FRAMED OPENING SHALL NOT BE LESS
 THAN 22 INCHES BY 30 INCHES (559 MM BY 762 MM) AND
 SHALL BE LOCATED IN A HALLWAY OR OTHER READILY
 ACCESSIBLE LOCATION.
  
 17)SHOW COMPLIANCE WITH R310 FOR EMERGENCY ESCAPE AND
 RESCUE OPENINGS AT THE SLEEPING ROOMS. SPECIFY THE
 SECOND FLOOR EGRESS WINDOWS ON THE PLANS.
  
 18) SUBMIT THE MANUFACTURER'S SPECIFICATIONS AND
 LISTING FOR THE OUTDOOR BBQ ON THE COVERED PORCH.
 INCLUDE SPECS. AND LISTING FOR HOOD IF ONE IS
 REQUIRED.
  
 19) SPECIFY THE CEILING FINISHES FOR THE FRONT PORCH,
 LOGGIA AND COVERED PATIO.
  
 20) THE ROOF/FLOOR DRAIN AT THE FRONT PORCH IS REQUIRED
 TO DISCHARGE AT LEAST 1 FOOT AWAY FROM THE STRUCTURE IN
 ACCORDANCE WITH R320.7.
  
 21) SHOW COMPLIANCE WITH R502.1.2 DRAFTSTOPPING
 REQUIRED.
 WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE
 CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS
 SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED
 SPACE DOES NOT EXCEED 1,000 SQUARE FEET (92.9 M 2 ).
 DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO
 APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS
 ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING
 MEMBRANE BELOW DRAFTSTOPPING SHALL BE PROVIDED IN
 FLOOR/CEILING ASSEMBLIES UNDER THE FOLLOWING
 CIRCUMSTANCES:
 1.CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. 2.
 FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN-WEB OR
 PERFORATED MEMBERS.
 R502.1.2.1 MATERIALS.
 DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ?-INCH
 (12.7 MM) GYPSUM BOARD, 3 / 8 -INCH (9.5 MM) WOOD
 STRUCTURAL PANELS, 3 / 8 -INCH (9.5 MM) TYPE 2-M-W
 PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY
 SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO
 THE FLOOR FRAMING MEMBERS UNLESS OTHERWISE APPROVED BY
 THE BUILDING OFFICIAL. THE INTEGRITY OF ALL DRAFTSTOPS
 SHALL BE MAINTAINED.
 SPECIFY THE MATERIAL AND LOCATIONS ON THE PLAN.
  
 22)REVISE THE TYPICAL DOOR JAMB DETAIL 7 ON A9. THE
 2X OR 1X BUCKS ARE REQUIRED TO BE THE FULL WIDTH OF THE
 JAMB. SEE R613.6.1.1
  
 23) REVISE GENERAL NOTE E(2) ON A9 TO SPECIFY ACI
 315-02 AND NOTE F(2) FROM SBC TO FBC. WHICH ARE THE
 CORRECT REFERENCES PER 2004 FBC RESIDENTIAL CHAPTER
 43.
  
 24) ON SHEET S1.01, NOTE 2 INCORRECTLY LISTS S3.01 AS
 THE SHEET CONTAINING THE WIDOW AND DOOR PRESSURES. THE
 TABLE IS LOCATED ON S 3.02.
  
 25) PLEASE SPECIFY THE COMPONENT AND CLADDING PRESSURES
 AT EACH OF THE OPENINGS ON THE PLANS BASED ON THE
 OPENING SIZES, EXPOSURE CATEGORY AND LOCATIONS. FBC *
 106.1.2
  
 26) ON SHEET S1.01 THE NOTE FOR CAP PLATE C REFERS TO
 DETAIL 8 ON S3.01, WHICH IS NOT CORRECT. PLEASE
 CORRECT. SEE 8 ON S3.02.
  
 27) ON PAGE A1 THE SUM OF 2 RISERS AND A TREAD IS
 23.95", WHICH IS NOT BETWEEN 24 AND 25 INCHES. PLEASE
 CORRECT.
  
 28) THE LB-3 BEAMS ARE NOT LISTED IN THE SECOND BEAM
 SCHEDULE ON SHEET S2.01.
  
 29) THE SIMPSON H10 OR USP RT16 ("R" IN SCHEDULE ON
 S2.02) WILL NOT WORK FOR ATTACHING THE FLOOR TRUSSES TO
 THE LEDGERS. THE FLOOR TRUSSES ARE 3-1/2" WIDE AND THE
 CONNECTORS HAVE A 1-9/16" OPENING FOR THE TRUSS.
  
 30) THE SCHEDULE SPECIFIES CONNECTOR "W" WHICH IS TWO
 SIMPSON H10 OR TWO USP RT16 TRUSS ANCHORS. SOME OF THE
 TRUSSES THAT HAVE THESE CONNECTORS SPECIFIED DO NOT
 EXTEND PAST THE 2 X 6 WALL SO THEY CAN NOT BE APPLIED
 TO EACH SIDE OF THE WALL AND THE TRUSS.
  
 31) CONNECTOR "L" IN THE SCHEDULE ON S2.02A SIMPSON
 MTSM 20,REQUIRES 4 CONCRETE SCREWS TO ACHIEVE THE
 UPLIFT SPECIFIED. ONLY 3 FASTENERS ARE SPECIFIED IN THE
 SCHEDULE. PLEASE CORRECT.
  
 32) CONNECTOR "N" ON S2.O2 , THE SIMPSON HTT22 IS
 INCORRECTLY SPECIFIED WITH 3/4" DIA. ANCHORS AND THE
 SIMPSON CATALOG SPECS. 5/8" DIA ANCHORS. PLEASE
 CORRECT.
  
 33) NOTE #4 ON SHEETS S2.01 AND S2.02 STATE SEE PLYWOOD
 NAILING SCHEDULE ON THIS SHEET AND THE SCHEDULE IS ON
 SHEET S3.02. PLEASE CORRECT.
  
 34) ALL OF THE DETAILS ON SHEET S3.02 ARE INCORRECTLY
 LABELED AS BEING ON S3.01.
  
 35) THE TRUSS LAYOUT IS REQUIRED TO BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE
 STRUCTURE.
  
 36) THE ROOF TRUSSES ARE REQUIRED TO HAVE A MINIMUM
 BOTTOM CORD LIVE LOAD OF 10 PSF. SEE TABLE R301.5.
  
 37) THE TRUSS DRAWING SUBMITTAL DOES NOT MEET THE
 REQUIREMENTS OF 61G-15-31.003. PLEASE SEPARATE THE
 DRAWINGS AND PLACE THEM WITH THE APPROPRIATE COVER
 SHEETS AND NUMBER THE DRAWINGS TO CORRESPOND TO THE
 NUMBERING ON THE COVERSHEETS.
  
 38) THE PLYWOOD SHEATHING FASTENING SCHEDULE FOR WALLS
 AND ROOFS ON S 3.02 SPECIFIES #8 SCREWS AND THE NOTE
 CALLS FOR 2-1/2" SELF DRILLING SCREWS FOR ATTACHING TO
 A METAL DECK.THE SHEATHING AND FRAMING FOR THIS
 PROJECT IS WOOD. PLEASE CORRECT. FBC R803.2.3.1
 REQUIRES 8D RING SHANK NAILS IN ALL ROOF ZONES.
  
 39)PRODUCT APPROVALS SUBMITTED WITH PERMIT
 APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO
 COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE
 APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE
 STATE.
  
 40)WPB ADMIN CODE 106.3* PRODUCT
 APPROVALS. THOSE PRODUCT WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 41) CIRCLE THE METHOD OF ATTACHMENT THAT WILL BE USED
 TO INSTALL THE ROOF TILE ON THE NOA.
  
 42)THE GENERIC PRESSURES IN THE SCHEDULE ON S3.02 ARE
 TOO HIGH FOR THE GARAGE DOORS. SEE TABLE R301.2(4).
  
 43)SUBMIT STATE OR MIAMI-DADE PRODUCT APPROVALS FOR
 THE NAN YA PLASTIC CORP. EXTERIOR DOORS OR THE
 MANUFACTURER CAN APPLY FOR LOCAL PRODUCT APPROVAL IN
 ACCORDANCE WITH RULE 9B-72.
  
 44) THE WEATHERSHIELD LEGACY FIXED WINDDOW NOA NO.
 05-0420.04 IS MISSING SHEET 4 OF 4 FROM DRAWING NO.
 1071.
  
 45) THE NOA NO. 03-1105.01 FOR THE PGT PW-701 WINDOW
 HAS BEEN REVISED BY NOA NO. 07-0418.06.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  
  
  
  
  
  
  