| Date |
Text |
| 2008-01-15 20:17:57 | ** DENIED 3RD REVIEW ** |
| | |
| | 1) NOTE: PLEASE SEE THE NOTES FROM PREVIOUS REVIEWS |
| | WHICH CLEARLY STATE PLANS MUST CONTAIN A DESIGN |
| | PROFESSIONAL TAKING RESPONSIBILITY OF THE PLANS PER |
| | 481.229, 471.025 OR 468. |
| | PLEASE SEE NONE OF THESE HAVE BEEN DONE. |
| | THE PREVIOUS PLANS CONTAINED A TITLE BLOCK FOR AN |
| | ENGINEER AND NOW THAT TITLE BLOCK HAS BEEN REMOVED? |
| | |
| | 2) NOTE: PLEASE SEE THE LOAD CALCULATIONS AS SUBMITTED |
| | ARE NOW ONLY BEING SUBMITTED FOR THE FIRST TIME UNDER |
| | RESIDENTIAL FOR THE FIRST REVIEW. |
| | PLEASE SEE NEC 220.60 AS THE HIGHER OF THE TWO LOADS |
| | FOR A/C SHALL BE FIGURED. AS THE OVER CURRENT |
| | PROTECTION FOR THE CU IS SHOWN SUBSTANTIALLY HIGHER IS |
| | THIS LOAD FOR THE CU HIGHER? |
| | IF SO, PLEASE ADJUST CALCULATIONS. |
| | PLEASE KNOW IF THIS NOT HIGHER THEN THESE ARE OK. |
| | |
| | PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW WERE NOT |
| | COMPLETELY ADDRESSED BY LISTING THE ARC FAULT PROTECTED |
| | CIRCUITS AS REQUIRED PER 408.4 AND 210.12. INSTEAD THE |
| | CODE SECTION WAS QUOTED ON THE PLANS. |
| | |
| | ** PLEASE SEE ITEM # 2 FOR THE ABOVE MAY BE PART OF A |
| | PROVISO HOWEVER THE PLANS SHALL CONTAIN A DESIGN |
| | PROFESSIONAL AS STATED ABOVE. |
| | |
| | |
| | * ** IMPORTANT** |
| | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR |
| | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL |
| | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS |
| | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT |
| | LEAVE ANY OLD/VOIDED SHEETS IN SETS. |
| | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS |
| | SHOULD BE SUBMITTED FOR REFERENCE. |
| | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY |
| | DELAYS. |
| | |
| | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY |
| | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE |
| | DO NOT HESITATE IN CONTACTING THIS OFFICE. |
| | PLEASE SEE BELOW FOR CONTACT INFORMATION. |
| | |
| | DEWEY PALMER |
| | ELECTRICAL PLAN REVIEW II |
| | CONSTRUCTION SERVICES DEPT. |
| | CITY OF WEST PALM BEACH |
| | 561-805-6717 |
| | [email protected] |