| 2007-09-21 17:01:22 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | 1. SHTS 1 & 2 THE DATE THE SIGNATURE AND SEAL ARE |
| | AFFIXED TO THE PLANS IS REQUIRED.--THE PRINTED NAME |
| | OF THE PERSON SEALING THE DOCUMENT IS REQUIRED ON EACH |
| | SHEET.--THE SIGNATURE IS REQUIRED. IT APPEARS THAT |
| | INITIALS ARE USED. IF INDEED THIS IS THE LEGAL |
| | SIGNATURE OF THE ARCHITECT, THEN A SIGNED, SEALED, |
| | NOTORIZED LETTER SHALL BE SUBMITTED INDICATING THE |
| | LEGAL SIGNATURE FOR OUR FILES. FAC 61G1-16.003, |
| | 61G1-16.004(5)(6) & FS 481.2055. |
| | |
| | 2. PLANS INDICATE THE OCCUPANCY OF THE BUILDING AS |
| | STORAGE. PER TABLES 1004.1.2 AND 104.3.1 TOILET ROOMS, |
| | A SERVICE SINK, A DRINKING FOUNTAIN AND POSSIBLY AN EYE |
| | WASH AND/OR EMERGENCY SHOWER MAY BE REQUIRED. ALSO SEE |
| | SECTIONS 403.2, 403.4 & 411. |
| | |
| | 3. PLEASE INDICATE WHAT WILL BE STORED IN THE STORAGE |
| | BUILDING. MSDS SHEETS MAY BE REQUIRED ACCORDING TO THE |
| | TYPE OF MATERIAL BEING STORED. SECTION 106.1.1. |
| | |
| | 4. HOT WATER WILL BE REQUIRED TO THE SERVICE SINK PER |
| | SECTION 607.1. PLEASE INDICATE THE LOCATION OF THE |
| | WATER HEATER. |
| | |
| | 5. SUBMIT A SANITARY ISOMETRIC RISER DIAGRAM SHOWING |
| | ALL PIPE SIZES, TRAPS & VENTS AS WELL AS A WATER |
| | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE SIZES, VALVES |
| | AND AN RPZV BACKFLOW ON THE WATER SERVICE TO THE |
| | BUILDING. SECTION 106.3.5.1.3(3)(5)(6)(8)(10)(13). |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, |
| | WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID |
| | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY |
| | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU |
| | FOR YOUR ANTICIPATED COOPERATION. |
| | |