| 2007-09-16 20:17:51 | BEAR LAKES COUNTRY CLUB 1901 VILLAGE BLVDBUILDING |
| | PLAN REVIEW |
| | PERMIT: 07080261 |
| | ADD: 1901 VILLAGE BLVD |
| | CONT: GSP & ASSOC |
| | TEL: (561)697-8444 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)PROVIDE FLOOD ZONE ELEVATION CERTIFICATE FOR NEW |
| | CONSTRUTION WITH BASE FLOOD ELEVATION, CITY CODE |
| | REQUIRES AN ADDITIONAL 6". THIS IS A LOMR REQUIRING A |
| | FINISH FLOOR HEIGTH OF 16'-6". |
| | |
| | 3) THERE IS ONLY ONE SET OF PLANS, (2) SETS OF ALL |
| | PLANS, PRODUCT APPROVAL, SUBMITTALS AND OR REPORTS WILL |
| | BE REQUIRED FOR PERMIT ISSUANCE. 106.1.2 ADDITIONAL |
| | INFORMATION REQUIRED. |
| | |
| | 4)110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE |
| | OF OCCUPANCY: |
| | A) THE EDITION OFTHE CODE UNDER WHICH THE PROJECT IS |
| | DESIGNED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| | PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, |
| | TABLE 601. |
| | D) THE OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED F) |
| | WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| | BUILDING PERMIT |
| | . |
| | 5)PLANS INDICATE PLYWOOD SUBSHEATHING TO BE WITHIN 6" |
| | OF GRADE, ALSO 2X4 STUDS. |
| | 2304.11.2.2 FRAMING. |
| | WOOD FRAMING MEMBERS, INCLUDING WOOD SHEATHING, WHICH |
| | REST ON EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 |
| | INCHES (203 MM) FROM EXPOSED EARTH SHALL BE OF |
| | NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. WOOD |
| | FRAMING MEMBERS AND FURRING STRIPS ATTACHED DIRECTLY TO |
| | MASONRY OR CONCRETE WALLS SHALL BE OF APPROVED |
| | NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. |
| | |
| | 2304.11.2.3 SLEEPERS AND SILLS. |
| | SLEEPERS AND SILLS ON A CONCRETE OR MASONRY SLAB THAT |
| | IS IN DIRECT CONTACT WITH EARTH SHALL BE OF NATURALLY |
| | DURABLE OR PRESERVATIVE-TREATED WOOD. |
| | |
| | 2304.11.2.5 WOOD SIDING. |
| | CLEARANCE BETWEEN WOOD SIDING AND EARTH ON THE EXTERIOR |
| | OF A BUILDING SHALL NOT BE LESS THAN 6 INCHES (152 MM) |
| | EXCEPT WHERE SIDING, SHEATHING AND WALL FRAMING ARE OF |
| | NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. |
| | |
| | 6) FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, |
| | PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) |
| | OF PRODUCT TESTING REPORTS ,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) WINDOWS |
| | B) DOORS |
| | C) TRUSS ANCHORS & STRAPS |
| | D) HARDIE PLANK |
| | E) ROOFING ASSEMBLIES: |
| | UNDERLAYMENT |
| | ROOF TILE |
| | |
| | 7)PRODUCT APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO |
| | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE |
| | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER |
| | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, |
| | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR |
| | SITE SPECIFIC FORM PER RULE 9B-72. |
| | |
| | 8) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | |
| | 9) THIS STRUCTURE USED TO BE A TRASH ENCLOSURE WITH A |
| | CONCRETE SLAB,HOW ARE YOU GOING TO TERMITE TREAT THE |
| | SLAB AND PROVIDE A VAPOR BARRIER? |
| | |
| | 10)PLANSFAIL TO INDICATE ATTIC VENTILATION: 1203.2 |
| | ATTIC SPACES. ENCLOSED ATTICS AND ENCLOSED RAFTER |
| | SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO |
| | THE UNDERSIDE OF ROOF FRAMING MEMBERS SHALL HAVE CROSS |
| | VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING |
| | OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN. |
| | BLOCKING AND BRIDGING SHALL BE ARRANGED SO AS NOT TO |
| | INTERFERE WITH THE MOVEMENT OF AIR. A MINIMUM OF 1 INCH |
| | (25 MM) OF AIRSPACE SHALL BE PROVIDED BETWEEN THE |
| | INSULATION AND THE ROOF SHEATHING. THE NET FREE |
| | VENTILATING AREA SHALL NOT BE LESS THAN 1 / 150 OF THE |
| | AREA OF THE SPACE VENTILATED, WITH 50 PERCENT OF THE |
| | REQUIRED VENTILATING AREA PROVIDED BY VENTILATORS |
| | LOCATED IN THE UPPER PORTION OF THE SPACE TO BE |
| | VENTILATED AT LEAST 3 FEET (914 MM) ABOVE EAVE OR |
| | CORNICE VENTS WITH THE BALANCE OF THE REQUIRED |
| | VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. |
| | |
| | 11) 1209.2 ATTIC SPACES. AN OPENING NOT LESS THAN 20 |
| | INCHES BY 30 INCHES (559 MM BY 762 MM) SHALL BE |
| | PROVIDED TO ANY ATTIC AREA HAVING A CLEAR HEIGHT OF |
| | OVER 30 INCHES (762 MM). A 30-INCH (762 MM) MINIMUM |
| | CLEAR HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT |
| | OR ABOVE THE ACCESS OPENING. |
| | |
| | 12)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, |
| | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE |
| | ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND A COPY |
| | OF THE PAID RECEIPT ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE INFORMATION. |
| | |
| | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS |
| | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF |
| | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST |
| | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT |
| | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC |
| | REQUIREMENT, THE SPECIFIC |
| | REQUIREMENT SHALL BE APPLICABLE. |
| | |