Plan Review Notes
Plan Review Notes For Permit 07080190
Permit Number 07080190
Review Stop B
Sequence Number 1
Notes
Date Text
2007-09-04 16:19:22 
  
 DENIED
  
 1)THE MAXIMUM ALLOWABLE SLOPE IS 1 IN 8,PLEASE
 PROVIDE ELEVATION AT PROPERTY LINE AND AT HOUSE TO
 DETERMINE COMPLIANCE
  
 2)HANDRAILS ARE REQUIRED ON AT LEAST ONE SIDE OF ALL
 RAMPS THAT EXCEED 1 IN 12 SLOPE, THE HANDRAIL HEIGHT
 MEASURED FROM THE SURFACE OF THE RAMP SHALL BE 34 - 38
 INCHES AND THE GRIP SIZE SHALL CONFORM WITH R311.5.6.3
 FBC RES. AND SHALL BE CONTINUOUS FOR THE FULL LENGTH OF
 THE RAMP
  
 3)CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE, AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE PER 106.1.1 FBC*
 DRAWINGS SHALL CONTAIN ONLY THE PLANS AND ELEVATIONS OF
 THE WORK TO BE PERMITTED
  
 4)PER 106.1.3 FBC* THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR
 PLANS AND SPECIFICATIONS "NO WHITE OUT, PENCIL OR INK"
  
 5)TERMITE TREATMENT IS REQUIRED ON ALL EXTERIOR
 CONCRETE WITHIN 1 FOOT OF PRIMARY STRUCTURE PER
 1816.1.6 OR R320.1.6 FBC
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716