| 2007-09-18 06:13:34 | BUILDING PLAN REVIEW |
| | PERMIT: 07080141 |
| | ADD: 5730 CORPORATE WAY |
| | CONT: LTL BUILDERS INC. |
| | TEL: (561) 478-1845 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE |
| | OF OCCUPANCY: |
| | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT IS |
| | DESIGNED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| | PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, |
| | TABLE 601. |
| | D) THE OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED |
| | F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| | BUILDING PERMIT |
| | . ------------------------------------- |
| | ) NUMBER OF UNITS |
| | ) NUMBER OF FLOORS |
| | ) NUMBER OF ROOMS |
| | ) SQ. FT. FOOTPRINT |
| | |
| | 3)106.3.3* PRODUCT APPROVALS- 2004 |
| | THOSE PRODUCTS THAT ARE REGULATED BY DCA RULE 9B-72 |
| | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. SUBMIT PRODUCT APPROVAL FOR |
| | THE METAL ROOFING SYSTEM INDICATED. |
| | |
| | 4)PROVIDE A WALL LEGEND SHOWING CLEARLY WHICH WALLS |
| | WILL BE DEMOED AND WHICH WALLS WILL REMAIN. ON SHEET 2 |
| | OF 4, WILL THE DOUBLE DOORS AND WALLS IN THE FOYER AREA |
| | BE REMOVED? IF SO, PRODUCT APPROVALS WILL BE REQUIRED |
| | FOR THOSE DOORS AND MULLIONS. |
| | |
| | 5)THE SCALE INDICATED ON THE DRAWINGS DOES NOT MATCH |
| | THE DIMENSION SHOWN. THE DIMENSIONS SHALL MATCH THE |
| | SCALE INDICATED. THE PLANS SHALL BE DRAWN TO A MINIMUM |
| | 1/8 INCH SCALE. THE BUILDING OFFICIAL MAY ESTABLISH |
| | THROUGH DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND |
| | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS |
| | RECORD RETENTION PROGRAM. WPB AMENDMENTS 106.1.3. |
| | |
| | 6)SUBMIT THE NORTH, SOUTH, EAST AND WEST ELEVATIONS. |
| | |
| | 7)WAS THE ENTRY TOTALLY COVERED INCLUDING THE TRELLIS |
| | AREA? IF NOT, SHOW THE OPEN AREA ABOVE ON THE |
| | DRAWINGS. |
| | |
| | |
| | 8)FBC 1503.4. UNLESS ROOFS ARE SLOPED TO DRAIN OVER |
| | EDGES, DESIGN AND INSTALLATION OF ROOF DRAINAGE SYSTEMS |
| | SHALL COMPLY WITH THE FBC PLUMBING CH. 11. INDICATE ON |
| | THE PLANS THE DRAINAGE SYSTEM OF THE NEW ROOF. |
| | |
| | 9)PROVIDE A FRAMING HEADER DETAIL FOR THE FOUR NEW |
| | WINGUARDFIXED WINDOWS. |
| | |
| | 10)ON SHEET T1 OF THE TRUSS PLACEMENT PLAN, INDICATE |
| | WHICH TRUSSES ARE DESIGN FOR THE ENCLOSE SECTION OF THE |
| | BUILDING AND THE TRUSSES DESIGN FOR THE OPEN SECTION. |
| | THE TRUSSES SHALL BE LABELED TO SHOW THE CORRECT |
| | PLACEMENT OF EACH TRUSS. THE FRONT AND REAR SECTION OF |
| | THE ROOF SHALL ALSO BE INDICATED. |
| | |
| | 11)SHOW A CONNECTION AND FRAMING DETAIL OF THE NEW |
| | 2X8 METAL STUDS AND INDICATE THE LOAD BEARING CAPACITY |
| | OF THE BEAM WHERE THE WALL IS CONSTRUCTED. |
| | |
| | |
| | 12) 2004 FL. BLDG CODE 1603.1.4 THE FOLLOWING |
| | INFORMATION RELATED TO WIND SHALL BE SHOWN ON THE |
| | CONSTRUCTION DRAWINGS, |
| | 1) - BASIC WIND SPEED, MPH |
| | 2) - WIND IMPORTANCE FACTOR, & BUILDING CATEGORY |
| | 3) - WIND EXPOSURE |
| | 4) - INTERNAL PRESSURE COEFFICIENT, |
| | 5) - COMPONENTS & CLADDING, THE DESIGN WIND PRESSURES |
| | IN TERMS OF PSF. |
| | |
| | 13)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |