2008-02-14 15:56:27BUILDING PLAN REVIEW
 PERMIT: 07080080
 ADD: 301 LAMBERTON DR.
 CONT: THE WEITZ CO.
 TEL: (561)719-0102
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND 2-14-08
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 **NOTED**
 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 **2ND REVIEW.**
 3)1802.2.1 QUESTIONABLE SOIL. WHERE THE
 SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE
 A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS
 CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE
 THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF
 SECTIONS 1802.4 THROUGH 1802.6. THIS IS A QUESTIONABLE
 SOIL AREA SO PLEASE PROVIDE THE SOIL REPORT.
  
 4) 2ND REVIEW **NOTED**
 HOWEVER, THE USE AND OCCUPANCY, INDICATED ON THE
 DRAWINGS (A-3) DOES NOT CORRESPOND WITH THE MAIN
 STRUCTURE.
  
 **2ND REVIEW.**
 5)SHEET S1.2 THE INTERNAL PRESSURE COEFFICIENT WAS
 CHANGED TO 0.55 FOR PARTIALLY ENCLOSED BUILDINGS,
 HOWEVER THE DESIGN CRITERIA ON S1.2 REFERS TO THE
 BUILDING AS AN ENCLOSED BUILDING. AS STATED IN THE
 FIRST REVIEW, THERE ARE SCREENS INDICATED ON EACH
 ELEVATION OF THE BUILDING. WITHOUT THE INSTALLATIONS OF
 WINDOWS, THE SCREENS WILL ALLOW THE PRESSURES TO BUILD
 IN THE BUILDING DURING HURRICANES /TORNADO OR OTHER
 NATURAL DISASTERS.
  
 6)OK
 7)OK
  
 2ND REVIEW **NOTED**
 8)THE STRUCTURAL SHEETS DO NOT PROVIDE UPLIFT FORCES
 TO BE RESISTED OR THE TYPE OF HARDWARE TO BE USED TO
 RESIST UPLIFT AND LATERAL LOADS. PROVIDE A BEAM AND
 COLUMN SCHEDULE INDICATING THE SIZE OF EACH COLUMN AND
 BEAM. WHAT IS THE SIZE OF L-1 / L-2 AND L-3?
  
 2ND REVIEW
 9)FBC 1609.1.4 COMPONENTS & CLADDING, PROVIDE 2
 COPIES (3 IF THRESHOLD OR RESIDENT INSPECTOR) OF
 PRODUCTS TESTING REPORTS, MISSING REPORTS ARE AS
 FOLLOWS
 A] TRUSS ANCHORS OK
 B] WALL LOUVERS
 C} PANEL WALL SYSTEMS-SCREEN (NOTE: DELETED FROM
 PLANS)
 D] TECO POST ANCHORS AND TECO POST CAPS.
  
 10)OK
  
 2ND REVIEW.
 11)WPB ADMIN CODE 106.3* THOSE PRODUCTS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FORJURISDICTIONAL APPROVAL.**ALL SETS OF
 PRODUCT APPROVAL SHALL BE APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. ONLY ONE SET HAS THE APPROVAL OF
 THE DESIGNER.**
  
 2ND REVIEW
 12)THE ROOF IS MISSING OR NOT IN COMPLIANCE WITH THE
 FOLLOWING ITEMS.
 ____1)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY:
 MEAN ROOF HEIGHT/ ROOF PITCH / ROOF DECK TYPE / AREA OF
 EACH ROOF TYPE
 ____ 2) FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG
 _XX_ 3) FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY
 YOU ARE USING.ALSO INDICATE WHICH FASTENER IF THE
 OPTIONS HAVE DIFFERENT PRESSURE LIMITATIONS.
 _XX_4)FOR THE FLAT DECK, SPECIFY THE ENHANCED
 FASTENING FOR CORNER AND PERIMETER ZONES.
 _XX_5)SEE PRODUCT LIMITATION #7.CALCULATIONS
 PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF
 CONSULTANT REQUIRED FOR ENHANCED FASTENING.
 XX6) THE SYSTEM PROVIDED INDICATES LIMITATION #9, NO
 ENHANCED FASTENING IS ALLOWED.
  
 13)OK
  
 2ND REVIEW
 14)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED,
 IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE
 ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE
 PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 15)OK
 16)OK
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 (561)805-6726
 (561) 805-6676
 [email protected]