| 2007-09-13 11:37:38 | CONSTRUCTION SERVICES DEPARTMENT |
| | 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH, |
| | FLORIDA33401 |
| | TEL:561-805-6713FAX: |
| | 561-805-6731 |
| | |
| | JAMES JOHNSTON,CBO PERMIT NO 07080077 |
| | BUILDING PLAN EXAMINERII PROJECT MORTON?S OF |
| | CHICAGO |
| | E-MAIL:JJOHNSTON @WPB.ORG ADDRESS 777 S. FLAGLER |
| | STREET CONTRACTOR RCC ASSOCIATES, INC. |
| | DATE SEPTEMBER 12, 2007 |
| | STRUCTURALPLANREVIEW |
| | |
| | 1. THE ARCHITECT OF RECORDIS MISSING THE FOLLOWING |
| | INFORMATION IN THEIR TITLE BLOCK, |
| | CERTIFICATE OF AUTHORIZATION NUMBER AS PERF.S. |
| | 489.219 |
| | 61G15-23.002 THE PRINTED NAME AND LICENSE NUMBER AND |
| | THE FIRMS CERTIFICATE OF AUTHORIZATION.THIS IS THE |
| | AUTHORIZATION NUMBER ASSOCIATED WITH THE ARCHITECTS |
| | LICENSE NUMBER THAT QUALIFIES THE FIRM PAYC.IN LIEU |
| | OF OBTAINING AN ADDITIONAL QUALIFYING NUMBER FROM THE |
| | STATE, THE ARCHITECT CAN REMOVE ALL REFERENCE TO THE |
| | COMPANY PAYC AND SIGN AS AN INDIVIDUAL. |
| | |
| | 2. TA1.1CODES |
| | STATEON COVER SHEET, FBC WITH 2005 AND 2006 |
| | REVISIONS |
| | |
| | 3. TA1.1CODES |
| | STATEON COVER SHEET, FBC 2004EXISTING BUILDINGS |
| | |
| | 4. TA1.1FBC EXISTING303ALTERATION LEVEL 1 TYPE OF |
| | CONSTRUCTION CLASSIFICATION,STATE ON COVER SHEET |
| | THIS IS A LEVEL 1 ALTERATION |
| | |
| | 5. CORRECTION SUBMITTAL |
| | WHEN RE-SUBMITTING CORRECTED PLANS FOR PERMITTING, |
| | PLEASE REMOVE AND REPLACE ANY SHEETS AS NECESSARY. |
| | INCLUDE A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER WITH A DESCRIPTION OF THE |
| | CORRECTIONS MADE. ALSO IDENTIFY THE SHEET OR |
| | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND. THIS |
| | SHALL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | 6. 109.3. |
| | 10.1 HURRICANE PROTECTION |
| | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW |
| | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO |
| | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION |
| | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN |
| | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN |
| | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| | DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION |
| | SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE |
| | DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| | DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH |
| | WINDS. |
| | |
| | 7. OCCUPANCY CLASSIFICATION |
| | A-2ASSEMBLY USES INTENDED FOR FOOD AND/OR DRINK |
| | CONSUMPTION INCLUDING, BUT NOT LIMITED TO: RESTAURANT |
| | |
| | |
| | |
| | 8. FBC1004.1.2OCCUPANT LOAD TABLE KITCHEN |
| | AREA CANNOT INCLUDE STORAGE/OFFICE/ LIQUOR/ ELECTRICAL |
| | ROOMS, SEE TABLE FOR CORRECT ALLOWANCES PER DEFINED |
| | SPACE |
| | |
| | |
| | 10. FBC803.1INTERIOR FINISHES FLAME SPREAD CLASS B |
| | FOR A-2 OCCUPANCYSEE TABLE803.5 |