| | DENIED |
| | |
| | 1)PROVIDE 2 COPIES OF A RECENT SURVEY SHOWING THE |
| | PROPOSED BUILDING/ADDITION WITH ALL SIDE AND REAR |
| | SETBACKS |
| | |
| | 2)DRAWINGS SHALL SHOW THE LOCATION OF ALLWORK, |
| | INCLUDING THE PROPOSED BUILDING(S) OR STRUCTURE(S) AND |
| | THEIR DISTANCES FROM THE EXISTING STRUCTURE(S) |
| | |
| | 3)IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE |
| | OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2 |
| | COPIES OF A SOIL TEST REPORT SHALL BE SUBMITTED PER |
| | R401.4 FBC RES. |
| | |
| | 4)PROVIDE BUILDING ELEVATIONS (TOP OF BEAM, MEAN ROOF |
| | HEIGHT, TOP OF OPENINGS, ETC) |
| | |
| | 5)PROVIDE DOOR SIZE,NOT ON DRAWING OR IN SCHEDULE |
| | |
| | 6)PROVIDE CORRECT DOOR AND WINDOW PRESSURES, BOTH ARE |
| | LOCATED IN ZONE 5 (MINIMUM 4 FT) PER FIG R301.2(8) FBC |
| | RES. |
| | |
| | 7)PER R803.3.2.1 FBC RES. ZONE 3 OF ROOF SHEATHING TO |
| | BE NAILED AT 4" O/C |
| | |
| | 8)NO HOT WATER HEATER IS SHOWN ON THE DRAWINGS, IS |
| | THE WASHING MACHINE TO USE COLD WATER ONLY ? |
| | |
| | 9)THE WINDOW AND DOOR PRODUCT APPROVALS THAT WERE |
| | SUBMITTED ARE NOT IMPACT RATED, IF THESE PRODUCTS ARE |
| | USED IMPACT PROTECTIVE DEVICES ARE REQUIRED AND PRODUCT |
| | APPROVALS MUST BE SUBMITTED |
| | |
| | 10)THE CITY OF WEST PALM BEACH REQUIRES THE |
| | FLORIDA STATE PRODUCT APPROVAL COVER SHEETS WHEN |
| | AVAILABLE. THEY CAN BE SEARCHED FOR ON |
| | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT |
| | SUBMITTED APPLICATIONS WILL BE DENIED |
| | |
| | 11)NO PRODUCT APPROVAL WAS SUBMITTED FOR THE SIMPSON |
| | TIES THAT ARE TO BE USED |
| | |
| | 12)NOTE: YALE OGRON HAVE THEIR OWN MULLIONS |
| | MIAMI-DADE # 06-0905.11 AND THE 1X SIZE IS MORE THAN |
| | ADEQUATE FOR THE 3 TYPE "A" WINDOWS THAT ARE JOINED |
| | TOGETHER. ALSO IT ALREADY HAS LOCAL PRODUCT APPROVAL IN |
| | THIS JURISDICTION SO THE MIAMI-DADE REPORT IS ALL THAT |
| | IS REQUIRED |
| | |
| | 13)SUBMIT ENGINEERED TRUSS DRAWINGS THAT |
| | COMPLY WITH R802.10.1 FBC WITH PERMIT |
| | APPLICATION OR BEFORE INSTALLATION THAT |
| | HAVE BEEN REVIEWED AND APPROVED BY THE |
| | DESIGNER OF RECORD |
| | |
| | 14)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED |
| | |
| | BLDG PLAN REVIEW |