| 2007-11-28 17:34:33 | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07080045 |
| | ADD: 1604 CLARE AVE |
| | CONT: BENITZ BUILDING LLC |
| | TEL: (561)659-4024 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 3RD |
| | ACTION: DENIED |
| | 11/28/07 |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)OK |
| | |
| | 3)BEFORE THE MOCK-UP ROOMS CAN BE APPROVED, MORE |
| | INFORMATION SHALL BE SUBMITTED. |
| | **NOTED**SHEETS WERE REMOVED FROM PACKAGE. |
| | 4)OK |
| | 5)OK |
| | |
| | 6) NOTE: IF THIS IS A TEMPORARY STURCTURE, IT SHALL |
| | CONFORM TO FBC. SEC 107. WHIC HAS A TIME LIMIT OF 180 |
| | DAYS. |
| | |
| | **NO RRESPONSE NOT ADDRESSED** |
| | 7)A LEGEND WITH THE WALL DETAILS SHALL ALSO BE |
| | SUBMITTED, ALONG WITH THE WALL FINISHES COMPLYING WITH |
| | FBC SEC. 803/ 804 AND 805. |
| | |
| | **NO RRESPONSE NOT ADDRESSED** |
| | 8)ADDITIONAL STRUCTURAL DETAIL ON THE FLOOR AND |
| | CEILING STUDS WILL ALSO BE REQUIRED, ALSO THE |
| | VENTILATION PER 1203 AND 1210 OF THE FBC. THE TYPE OF |
| | GLASS AT THE BATHROOM SHOWER FBC.2406/ |
| | **NEW** |
| | SHOW THE ATTACHMENT DETAIL OF THE FLOOR JOIST TO THE |
| | EXISTING FLOOR INDICATING THE MATERIALS. THE HEADER AND |
| | SILL FRAMING DETAIL SHALL BE SHOWN ON THE DRAWINGS. THE |
| | BUILDING OFFICIAL MAY REQUIRE DETAILS, COMPUTATIONS, |
| | STRESS DIAGRAMS AND OTHER DATA NECESSARY TO DESCRIBE |
| | THE CONSTRUCTION OR INSTALLATION OF THE PROJECT. WPB |
| | AMENDMENTS 106.1.2 |
| | |
| | 9) A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | THERE MAY BE OTHER COMMENTS FOR ACCESSIBILITY AND FAIR |
| | HOUSING DEPENDING ON THE USE AND OCCUPANCY OF THE |
| | BUILDING. |
| | |
| | **NEW** |
| | 10)OK. |
| | |
| | **NO RRESPONSE NOT ADDRESSED** |
| | 11)SHOW THE ACCESSIBLE ROUTE TO THE UNIT MEET THE |
| | REQUIREMENTS OF SECTION 11-4.3.1 |
| | **NEW** FBC 11-4.5.2 CHANGES IN LEVEL GREATER THAN ? |
| | INCH SHALL BE ACCOMPLISHED BY MEANS OF A RAMP THAT |
| | COMPLIES WITH SECTION 11-4.7 OR 11-4.8. SHOW |
| | COMPLIANCE. THIS IS REQUIRED DUE TO THE FACT THAT THERE |
| | ARE STEPS LEADING TO THE ENTRANCE OF THE ROOM. ALL |
| | RAMPS SHALL BE STABLE, FIRM, SLIP RESISTANT, AND SHALL |
| | COMPLY WITH SECTION 11-4.5.LANDINGS AT RAMPS SHALL |
| | MEET THE REQUIREMENTS OF 11-4.8.4 AND 11-4.13.6 SHOW IN |
| | DETAIL DRAWINGS HOW THESE REQUIREMENTS WILL BE |
| | ACCOMPLISHED |
| | |
| | **NO RRESPONSE NOT ADDRESSED** |
| | 12)SHOW ON THE ON THE DRAWINGS THE EXISTING BATHROOM |
| | FACILITIES. CONSTRUCTION DOCUMENTS SHALL BE OF |
| | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND |
| | EXTENT OF THE WORK PROPOSED. FBC 106.1.1. |
| | |
| | **NO RRESPONSE NOT ADDRESSED** |
| | 13)A DETAIL LETTER INDICATING THE USE/ OCCUPANCY AND |
| | PURPOSE OF THE STRUCTURE CAN ALSO SUBMITTED BY THE |
| | OWNER. THE LETTER SHALL BE CLEAR AND PRECISE STATING |
| | THAT THE SPACE IS ONLY USED AS A SHOW ROOM. |
| | |
| | **NEW** |
| | 14)FBC 907.2.10.1 AN APPROVED SINGLE-STATION SMOKE |
| | ALARM SHALL BE INSTALLED IN EVERY GUESTROOM AND EVERY |
| | LIVING AREA AND SLEEPING ROOM WITHIN A GUEST SUITE. |
| | |
| | 15)106.1.1* W.P.B. ADMINISTRATIVE CODE/2004 DRAWINGS |
| | & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM |
| | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, |
| | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE |
| | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC TO |
| | THE TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR |
| | IN PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED |
| | AS A SUBSTITUTE FOR SPECIFIC INFORMATION". CONSTRUCTION |
| | DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE |
| | LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND |
| | SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS |
| | OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |