 BUILDING PLAN REVIEW
 PERMIT: 07080045
 ADD: 1604 CLARE AVE
 CONT: BENITZ BUILDING LLC
 TEL: (561)659-4024
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW: 2ND
 ACTION: DENIED
 10/10/07
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)OK
  
 3)BEFORE THE MOCK-UP ROOMS CAN BE APPROVED, MORE
 INFORMATION SHALL BE SUBMITTED.
 **NOTED** HOWEVER, ALL DRAWINGS SPECIFICATIONS AND
 ACCOMPANYING DATA SHALL BE SIGNED SEAL AND DATED BY THE
 DESIGN PROFESSIONAL AS REQUIRED BY FLORIDA STATUTES 471
 AND 481. IF THE 11X17 SHEETS ARE SUBMITTED AS
 ADDITIONAL INFORMATION, THEY SHALL BE SIGNED BY THE
 PERSON RESPONSIBLE FOR THE DRAWINGS.
  
 4)110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING:
 A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE
 PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6,
 TABLE 601.
 D) THE OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED
 F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED.
 G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE
 BUILDING PERMIT
 . -------------------------------------
 ) NUMBER OF UNITS
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) NUMBER OF BEDROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. FOOTPRINT
 **NOTED, HOWEVER, ALL THE INFORMATION SHALL BE
 INDICATED ON THE DRAWINGS**
  
 5)OK
  
 6)IF THIS IS A TEMPORARY STURCTURE, IT SHALL CONFORM
 TO FBC. SEC 107. WHIC HAS A TIME LIMIT OF 180 DAYS.
 **NO RESPONSE NOT ADDRESSED**
  
 7)A LEGEND WITH THE WALL DETAILS SHALL ALSO BE
 SUBMITTED, ALONG WITH THE WALL FINISHES COMPLYING WITH
 FBC SEC. 803/ 804 AND 805.
 **NO RESPONSE NOT ADDRESSED**
  
 8)ADDITIONAL STRUCTURAL DETAIL ON THE FLOOR AND
 CEILING STUDS WILL ALSO BE REQUIRED, ALSO THE
 VENTILATION PER 1203 AND 1210 OF THE FBC. THE TYPE OF
 GLASS AT THE BATHROOM SHOWER FBC.2406/
 **NEW**
 SHOW THE ATTACHMENT DETAIL OF THE FLOOR JOIST TO THE
 EXISTING FLOOR INDICATING THE MATERIALS. THE HEADER AND
 SILL FRAMING DETAIL SHALL BE SHOWN ON THE DRAWINGS. THE
 BUILDING OFFICIAL MAY REQUIRE DETAILS, COMPUTATIONS,
 STRESS DIAGRAMS AND OTHER DATA NECESSARY TO DESCRIBE
 THE CONSTRUCTION OR INSTALLATION OF THE PROJECT. WPB
 AMENDMENTS 106.1.2
  
 9) A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
 THERE MAY BE OTHER COMMENTS FOR ACCESSIBILITY AND FAIR
 HOUSING DEPENDING ON THE USE AND OCCUPANCY OF THE
 BUILDING.
  
 **NEW**
 10)THE FUNCTIONAL UNIT SHALL BE ACCESSIBLE AND SHALL
 MEET THE REQUIREMENTS OF THE ACCESSIBILITY CODE. SINKS
 SHALL MEET THE REQUIREMENTS OF SECTION 11-4.24. SHOWER
 STALLS SHALL COMPLY WITH SECTION 11-4.21. A SHOWER
 SPRAY UNIT WITH A HOSE AT LEAST 60 INCHES LONG THAT CAN
 BE USED BOTH AS A FIXED SHOWER HEAD AND AS A HAND-HELD
 SHOWER SHALL BE PROVIDED 11-4.20.6.11-4.26.1 GENERAL.
 ALL HANDRAILS , GRAB BARS , AND TUB AND SHOWER SEATS
 REQUIRED TO BE ACCESSIBLE BY SECTION 11-4.1 , 11-4.8 ,
 11-4.9 , 11-4.16 , 11-4.17 , 11-4.20 OR 11-4.21 SHALL
 COMPLY WITH SECTION 11-4.26 .
  
 11)SHOW THE ACCESSIBLE ROUTE TO THE UNIT MEET THE
 REQUIREMENTS OF SECTION 11-4.3.1
  
 12)SHOW ON THE ON THE DRAWINGS THE EXISTING BATHROOM
 FACILITIES. CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED. FBC 106.1.1.
  
 13)A DETAIL LETTER INDICATING THE USE/ OCCUPANCY AND
 PURPOSE OF THE STRUCTURE CAN ALSO SUBMITTED BY THE
 OWNER. THE LETTER SHALL BE CLEAR AND PRECISE STATING
 THAT THE SPACE IS ONLY USED AS A SHOW ROOM.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER