| 2007-08-24 17:00:19 | RESIDENTIALADDITION AND RENOVATION BUILDING REVIEW |
| | FIRST CHECKLIST. |
| | REVIEW UNDER 2004 FLORIDA RESIDENTIAL CODE AND FBC 2004 |
| | WITH 2006/2007 REVISIONS. |
| | |
| | 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY |
| | SEC. 713.13 FLORIDA STATUTE. |
| | |
| | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD |
| | (561)233-5115)TO VERIFY IF IMPACT FEES ARE DUE. BRING |
| | BACK STAMPED PLANS AND COPY OF PAID RECEIPT IF IMPACT |
| | FEES ARE DUE. |
| | |
| | 3- PROVIDE PRODUCT APPROVALS FOR: |
| | A) FRENCH DOORS "INSWING AND OUTSWING" AS SHOWN ON |
| | PLANS. INCLUDING FRENCH DOORS WITH SIDELITES |
| | ASSEMBLIES. |
| | |
| | B) ARCHED AND RECTANGULAR CASEMENT WINDOWS AS SHOWN |
| | ON EXTERIOR ELEVATIONS. |
| | |
| | C) FIXED WINDOWS AS SHOWN ON PLANS. |
| | |
| | D) FRENCH DOORS WITH TRANSOMABOVE AS SHOWN ON |
| | EXTERIOR ELEVATIONS. |
| | |
| | E) WINDOW MULLION. AND, CLEARLY INDICATE MULLION |
| | SIZE AND ATTACHMENT TO VERIFY COMPLIANCE WITH THE |
| | DESIGN PRESSURES CALCULATED BY THE ENGINEER. |
| | |
| | F) FLAT ROOF.AND,CLEARLY IDENTIFY SPECIFIC |
| | ASSEMBLY TO BE INSTALLED.ALSO, IF SELECTED ASSEMBLY |
| | IS LIMITED BY GENERALLIMITATION #7, THEN PROVIDE RAS |
| | 117 CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND |
| | CORNER AREAS. SEE GENERAL LIMITATION #7 ON LAST PAGE OF |
| | NOA. IF THIS LIMITATION REQUIRES CALCULATIONS TO BE |
| | DONE BY ANY OF THE LISTED PROFESSIONALS, THEN |
| | CALCULATIONSMUST BE DONE BY ANY ONE OF THEM. |
| | IF-SELECTED ASSEMBLY IS LIMITED BY GENERAL LIMITATION |
| | #9, THEN IT CAN'T BE USED IN THIS AREA. |
| | |
| | G) ROOF TILE. |
| | |
| | H) GARAGE DOORS. |
| | |
| | I) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON |
| | PLANS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL COVER |
| | PAGE AND SPECIFIC SHEET WHERE CONNECTOR IS SHOWN TO |
| | SAVE PAPER. |
| | |
| | 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 5- ONLY TWO SETS OF PLANS AND PRODUCT APPROVALS ARE |
| | REQUIRED. NOT THREE. |
| | |
| | 6- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. |
| | 13-600.0 OF FBC 2004. |
| | |
| | 7 PROVIDE COMPLETE ICYNENE SPECIFICATIONS. SEC. 106.1.2 |
| | CITY AMENDMENTS TO FBC 2004. |
| | |
| | 8- PLANS TO SPECIFY CONSTRUCTION TYPE AS REQUIRED BY |
| | SEC. 602.1 FBC 2004. |
| | |
| | 9- PROVIDE COMPLETE DIMENSIONSFOR NEW STEPS TO VERIFY |
| | COMPLIANCE WITH SEC. R311.5.3 OF 2004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 10- DESIGNER OF RECORD TO SPECIFY ROOF TILE ATTACHMENT |
| | AS REQUIRED BY SEC. 106.1.1.2 OF CITY AMENDMENTS TO FBC |
| | 2004.IF USING NAILS OR SCREWS, THEN SPECIFY SIZE AND |
| | NUMBER TO BE USED. IF USING ADHESIVE, THEN SPECIFY |
| | WHICH ONE AND PROVIDE PRODUCT APPROVAL AS REQUIRED BY |
| | DCA RULE 9B-72. |
| | |
| | 11- SHEET A10: PROVIDE COMPLETE SPECIFICATIONS FOR |
| | ATTACHMENT OF STRUCTURAL BUCKS TO EXISTING AND NEW |
| | COLUMNS. STRUCTURAL PLANS DON'T PROVIDE THIS |
| | INFORMATION. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 12- SHEET S4: |
| | A) UPDATEREFERENCE STANDARDS SPECIFIED ALL GENERAL |
| | NOTES. SEECHAPTER 43 OF 2004 FLORIDA RESIDENTIAL CODE |
| | AND CHAPTER 35 OF FBC 2004 FOR CORRECTREFERENCE |
| | STANDARDS AND YEAR ADOPTED BY THE CODE AND REVISE ALL |
| | NOTES AS REQUIRED. |
| | |
| | B) PROVIDE SOIL TEST REPORT REFERENCED ON FOUNDATION |
| | NOTE #1. |
| | |
| | C) SPECIFY CONNECTOR AT TOP OF STEEL COLUMN SC-1. |
| | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |
| | D) PLYWOOD ROOF SHEATHING THICKNESS SPECIFIED ON |
| | WOOD NOTE 5(A) DOESN'T MATCH THICKNESSSPECIFIED ON |
| | DETAILS SHOWN ON SHEET S6. REVISE AS REQUIRED TO |
| | MATCH. |
| | |
| | E) REVISE SECTION SPECIFIED ON NOTE #1 BELOW THE |
| | WIND LOAD SCHEDULE CHART. SEE FBC 2004 FOR CORRECT |
| | SECTION TO BE CITED. |
| | |
| | 13- SHEET S5: |
| | A) REVISE DIMENSION SHOWN ON TYPICAL STEP FOOTING |
| | DETAIL. SEE ITEMCOMMENTS ON ITEM #9 ABOVE. |
| | |
| | B) REVISE NOTE #1 BELOW TYPICAL WOOD BUCK TO |
| | CONCRETE CONNECTION DETAIL. REVISE FBC 2001 AND SECTION |
| | CITED FOR OPENING PROTECTION. SEE FBC 2004 FOR CORRECT |
| | SECTION. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |