Text |
| 2007-09-04 08:04:33 | SIGN BUILDING REVIEW FIRST CHECKLIST. | | | REVIEW DONE UNDER FBC 2004 WITH 2007 REVISIONS. | | | | | | 1- DETAIL SECTION SHOWN ON 8 1/2"X 11" SHEET DOESN'T | | | MATCH SECTION DETAIL SHOWN ON 11" X 17" SHEET.DETAIL | | | AND SPECIFICATIONS NEED TO MATCH. | | | | | | 2-ENGINEERING11" X 17"SHEET: | | | A) UPDATE ASCE 7 EDITION USED.FBC 2004 REFERENCE | | | ASCE 7-02, NOT ASCE 7-98.REVISE AS REQUIRED. | | | | | | B) CLEARLY INDICATE SPACING FOR CONCRETE EXPANSION | | | ANCHORS.SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | C) PROVIDE COMPLETE SPECIFICATIONS FOR ATTACHMENT OF | | | ALUMINUM CHANNEL LETTERS TO RACEWAY. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|