Plan Review Notes
Plan Review Notes For Permit 07070921
Permit Number 07070921
Review Stop B
Sequence Number 2
Notes
Date Text
2007-12-28 18:37:03PROJECT: 1100 NORTH OLIVE AVENUE
  
 PROJECT DETAIL: CHANGE OF OCCUPANCY/GROUP R-3 TO GROUP
 B CLASSIFICATION
  
 CODE REVIEW:
  
 2004 FLORIDA EXISTING BUILDING CODE W/2006 REVISIONS
 2004 FLORIDA BUILDING CODE W/ 2006 REVISIONS
 CITY OF WEST PALM BEACH/ FLORIDA BUILDING CODE
 ADMINISTRATION AMENDMENTS, CHAPTER 1, 2004 EDITION
  
 STATUS: FAILED
  
 COMMENTS:
  
 1) 61G1-16.004 TITLE BLOCK.
 A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR
 INTERIOR DESIGN DRAWINGS AND SPECIFICATION
 IDENTIFICATION SHEETS. THE TITLE BLOCK
 MUST, AT A MINIMUM, CONTAIN THE FOLLOWING INFORMATION:
  
  
 (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER.
 (2) FIRM LICENSE NUMBER.
 (3) NAME OR IDENTIFICATION OF PROJECT.
 (4) DATE PREPARED.
 (5) A SPACE FOR THE SIGNATURE AND DATED SEAL.
 (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING
 THE DOCUMENT.
 SPECIFIC AUTHORITY 481.2055 FS. LAW IMPLEMENTED
 481.203(6), 481.203(8), 481.2131(1),
 481.219(3),(4),(5), 481.221,
 481.225(1)(E),(G), 481.2251(1)(H) FS. HISTORY?
 NEW 9-7-00.
  
 2) PLEASE INDICATE THE PROPOSED OCCUPANCY LOAD OF THE
 GROUP B CLASSIFICATION.
  
 3) PLEASE PROVIDE A LIFE SAFETY PLAN INDICATING TRAVEL
 DISTANCES/COMMON PATH OF TRAVEL/EXIT SIGNS ETC:
  
 FEBC 705.3EXIT SIGNS.
 MEANS OF EGRESS FROM THE HIGHEST WORK AREA FLOOR TO THE
 FLOOR OF EXIT DISCHARGE SHALL BE PROVIDED WITH EXIT
 SIGNS IN ACCORDANCE WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 4) PLEASE SHOW THE ACCESSIBLE ROUTE/ACCESSIBLE MEANS OF
 EGRESS. PLEASE INCLUDE THE ACCESSIBLE PARKING SPACES
 DEPICTING DIMENSIONS. THE ACCESSIBLE ROUTE SHALL COMPLY
 WITH SECTION 11-4.1 OF THE FLORIDA BUILDING CODE.
  
 5) THE TOP LANDINGS AT THE ACCESSIBLE RAMPSHOWN ON
 SHEET A-1 DO NOT MEET THE MINIMUM REQUIREMENTSOF
 SECTION 11-4.8.4:
  
 11-4.8.4 LANDINGS.
  
 RAMPS SHALL HAVE LEVEL LANDINGS AT BOTTOM AND TOP OF
 EACH RAMP AND EACH RAMP RUN. LANDINGS SHALL HAVE THE
 FOLLOWING FEATURES:
 (1) THE LANDING SHALL BE AT LEAST AS WIDE AS THE RAMP
 RUN LEADING TO IT.
 (2) ALL LANDINGS ON RAMPS SHALL BE NOT LESS THAN 60
 INCHES (1524 MM) CLEAR, AND THE BOTTOM OF EACH RAMP
 SHALL HAVE NOT LESS THAN 72 INCHES (1829 MM) OF
 STRAIGHT AND LEVEL CLEARANCE.
 (3) IF RAMPS CHANGE DIRECTION AT LANDINGS, THE MINIMUM
 LANDING SIZE SHALL BE 60 INCHES BY 60 INCHES (1525 MM
 BY 1525 MM).
 (4) IF A DOORWAY IS LOCATED AT A LANDING, THEN THE AREA
 IN FRONT OF THE DOORWAY SHALL COMPLY WITH SECTION
 11-4.13.6.
  
 6) PLEASE SHOW THAT THE RAMP HANDRAILS COMPLY WITH
 SECTION 11-4.8.5:
  
 11-4.8.5 HANDRAILS.
  
 IF A RAMP RUN HAS A RISE GREATER THAN 6 INCHES (150 MM)
 OR A HORIZONTAL PROJECTION GREATER THAN 72 INCHES (1830
 MM), THEN IT SHALL HAVE HANDRAILS ON BOTH SIDES.
 HANDRAILS ARE NOT REQUIRED ON CURB RAMPS OR ADJACENT TO
 SEATING IN ASSEMBLY AREAS. HANDRAILS SHALL COMPLY WITH
 SECTION 11-4.26 AND SHALL HAVE THE FOLLOWING FEATURES:
 (1) HANDRAILS SHALL BE PROVIDED ALONG BOTH SIDES OF
 RAMP SEGMENTS. THE INSIDE HANDRAIL ON SWITCHBACK OR
 DOGLEG RAMPS SHALL ALWAYS BE CONTINUOUS. (2) HANDRAILS
 ON RAMPS WHICH ARE NOT CONTINUOUS SHALL EXTEND NOT LESS
 THAN 18 INCHES (457 MM) BEYOND THE SLOPED SEGMENT AT
 BOTH THE TOP AND BOTTOM, AND SHALL BE PARALLEL TO THE
 FLOOR OR GROUND SURFACE.
 (3) THE CLEAR SPACE BETWEEN THE HANDRAIL AND THE WALL
 SHALL BE 1? INCHES (38 MM).
 (4) GRIPPING SURFACES SHALL BE CONTINUOUS.
 (5) TOP OF HANDRAIL GRIPPING SURFACES SHALL BE MOUNTED
 BETWEEN 34 INCHES AND 38 INCHES (865 MM AND 965 MM)
 ABOVE RAMP SURFACES.
 (6) ENDS OF HANDRAILS SHALL BE EITHER ROUNDED OR
 RETURNED SMOOTHLY TO FLOOR, WALL, OR POST.
 (7) HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
  
 7) PLEASE SHOW THAT THE STAIRS AND HANDRAILING MEET THE
 REQUIREMENTS OF SECTION 11-4.9 OF THE FLORIDA
 ACCESSIBILITY CODE. THE EXISTING STAIRS SHALL MEET THE
 MINIMUM REQUIREMENTS OF SECTION
 703.1FEBC:
  
 703.1EXISTING SHAFTS AND VERTICAL OPENINGS. EXISTING
 STAIRWAYS THAT ARE PART OF THE MEANS OF EGRESS SHALL
 COMPLY WITH THE APPROPRIATE SECTIONS OF THE FLORIDA
 FIRE PREVENTION CODE.
  
 8) PLEASE INDICATE THE ACCESSIBLE BATHROOM. SHOW CLEAR
 FLOOR SPACE, HEIGHT AND WALL DIMENSIONS OF LAVATORY AND
 WATER CLOSET. ALSO, INDICATE THE CLEAR OPENING DOOR
 WIDTH. GRAB BARS SHALL BE SHOWN ANDSHALL MEET THE
 MINIMUM REQUIREMENTS OF SECTION 11-4.26.
  
 9) THE MEANS OF EGRESS SHALL MEET THE MINIMUM
 REQUIREMENTS OF SECTION 605, FLORIDA EXISTING BUILDING
 CODE.
  
 10) PLEASE INDICATE THE EXISTING INTERIOR WALL AND
 CEILING FINISHES AS PER THE FOLLOWING:
  
 FEBC 812.3.1MINIMUM REQUIREMENTS.
 REGARDLESS OF T HE OCCUPANCY GROUP INVOLVED, THE
 FOLLOWING REQUIREMENTS SHALL BE MET:
 1. THE CAPACITY OF THE MEANS OF EGRESS SHALL COMPLY
 WITH FLORIDA BUILDING CODE, BUILDING.
 2. THE INTERIOR FINISH OF WALLS AND CEILINGS SHALL
 COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING
 CODE, BUILDING FOR THE NEW OCCUPANCY GROUP.
 3. COMPLIANCE WITH THE FLORIDA FIRE PREVENTION CODE.
  
 END OF REVIEW
  