| Date |
Text |
| 2007-08-30 13:25:56 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: |
| | |
| | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). |
| | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR |
| | NOI. |
| | YOU CAN GET NOI INFO FROM |
| | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ |
| | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), |
| | EFFECTIVE MAY 1, 2003 |
| | 2. PLEASE SHOW ON DRAWING ALL CITY STANDARDS NOTES FOR |
| | SIDEWALK, DRIVEWAY, APPROACH, PARKINGS, HANDICAP |
| | PARKINGS, DUMPSTER ENCLOSURE, YOU CAN GET A C D FROM |
| | 1000, 45 STREET FOR ALL THESE CITY STANDARDS NOTES. |
| | PHONE# 494-1040 |
| | 3. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE |
| | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION |
| | MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | 4. FLOOR ELEVATION, CENTER LINE OF ROAD , SIDEWALK |
| | ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, 25, 100 |
| | YEAR FLOOD CRITERIATO DETERMINE THE FLOOR ELEVATION, |
| | PLEASE SHOW IN YOUR STORM WATER CALS. |
| | 5. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE |
| | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL |
| | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, |
| | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE |
| | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED |
| | IN PRE & POST STORM WATER QUALITY CALCULATIONS. |
| | 6. HOW DO YOU CONNECT TO THE STORM WATER PIPES IN YOUR |
| | SITE? PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR |
| | SITE SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES |
| | FROM ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF |
| | THE CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, |
| | BLEEDING ELEVATION, ETC ON DRAWINGS, CALCULATION FOR |
| | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET |
| | DETENTION AREAS IN STORM WATER CALS. |
| | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND |
| | YOUR SITE FOR STORM WATER DRAIN. |
| | 8. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, &STORM |
| | WATER QUALITY CALCULATIONS, |
| | 9. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION |
| | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT |
| | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE |
| | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & |
| | PARTICLES. |
| | 10. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |