| 2007-08-11 16:43:00 | BUILDING PLAN REVIEW |
| | PERMIT: 07070800 |
| | ADD: 1700 PBL BLVD |
| | CONT: HOLT LEE CONST. INC. |
| | TEL: (954)725-4881 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW: 1ST |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) 2004 FBC EXISTING |
| | 301.5A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE |
| | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO |
| | SECTIONS 303, 304 AND 305 OF THIS CODE. |
| | |
| | 3)ALL PLANS SUBMITTED AFTER OCTOBER, 1, |
| | 2004 SHALL BE DESIGNED TO THE 2004 |
| | FLORIDA BUILDING CODE/WITH THE 2006 REVISIONS. |
| | |
| | 4)SHEETS D1 AND D2 IS MISSING THE PRINTED NAME AND |
| | NUMBER OF THE PERSON SEALING THE PLANS. |
| | FAC. 61G1-16.004 |
| | |
| | 5)THE DBPR WEB-SITESHOWS MPA DESIGN INC INTERIOR |
| | DESIGN BUSINESS HAS A "DELIQUENT" STATUS. EITHER REMOVE |
| | THIS INFORMATION FROM THE DRAWINGS OR THE STATUS SHALL |
| | BE BROUGHT UP TO DATE WITH AN ACTIVE STATUS. SEE |
| | INFORMATION SHEET FROM DBPR IN PACKAGE. |
| | |
| | 6)PROVIDE AN INTERIOR FINISH SCHEDULE FOR EACH ROOM |
| | INDICATING THE FLAME/SMOKE DEVELOPEMENT COMPLYING WITH |
| | FBC. 803 / 804 AND 805. |
| | |
| | 7)ON SHEET A1 SHOW A CROSS CUT SECTION OF THE NEW |
| | SLAB IN RELATION TO THE DOOR THRESHOLD. FBC 11-4.13.8. |
| | ALSO SEE 11-4.5.2. INDICATE THE SLOPE. |
| | |
| | 8)PROVIDE PRODUCT APPROVAL FOR THE NEW DOOR F-3. |
| | FBC.106.3.3* PRODUCT APPROVALS- 2004 |
| | THOSE PRODUCTS THAT ARE RGULATED BY DCA |
| | RULE 9B-72 SHALL BE REVIEWED AND |
| | APPROVED IN WRITTING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL. |
| | |
| | 9)FBC. 11-4.24. THE SINK IN THE CONFERENCE ROOM SHALL |
| | A CLEAR FLOOR SPACE OF AT LEAST 30 INCHES BY 48 INCHES |
| | IN FRONT OF IT TO ALLOW FORWARD APPROACH. THE SPACE |
| | SHALL EXTEND A MAXIMUM OF 19 INCHES. UNDERNEATH THE |
| | SINK. NOTHING SHALL BLOCK THE FORWARD APPROACH. |
| | |
| | 10)IF THERE IS A RECEPTIONIST COUNTER, IT SHALL MEET |
| | THE REQUIREMENTS OF FBC. 11-7WHEREA PORTION OF THE |
| | MAIN COUNTER IS A MINIMUM OF 36 INCHES IN LENGTH AND A |
| | MAXIMUM HEIGHT OF 36 INCHES. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected] |