| Plan Review Notes For Permit 07070682 |
| Permit Number |
07070682 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2007-08-20 11:04:08 | *****DENIED***** | | | | | | | | | 1.THE PROJECT SITE, INCLUDING THE SUITE NUMBER, SHALL | | | BE IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 2.PLEASE INDICATE THE EXISTING AS WELL AS THE | | | PROJECTED USE AND OCCUPANCY CLASSIFICATION. | | | | | | 3.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 4.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 5.THE SCOPE OF WORK SHALL NOT INTERFERE OR HINDER | | | EMERGENCY ACCESS TO THE SAID PROPERTY OR THE VICINITY | | | THEREOF. | | | | | | 6.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 7.PROVIDE A LIFE SAFETY PLAN WHICH SHOWS TRAVEL | | | DISTANCE TO THE EXIT, LOCATION OF FIRE EXTINGUISHER(S), | | | EXIT AND EMERGENCY LIGHTS. | | | | | | 8.SPECIFY THE INTERIOR FINISH MATERIAL MATERIALS FOR | | | THE NEW WALLS IN TERMS OF CLASS A, CLASS B, OR CLASS | | | C. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|