2007-08-31 09:52:252004 FBC W/2007 SUPPLEMENTS
 INSTALL HURRICANE IMPACT SCREENS
 2ND REVIEW
  
 DENIED BY BUILDING
  
 1) THE IMPACT SCREEN MULLIONS DO NOT HAVE STATE OR
 MIAMI-DADE PRODUCT APPROVALS AS REQUIRED BY FAC RULE
 9B-72. THE MANUFACTURER IS REQUIRED TO APPLY FOR
 LOCAL/SITE SPECIFICPRODUCT APPROVAL. SEE ATTACHMENT.
 FBC 1609.1.4 REQUIRES IMPACT-RESISTANT PRODUCTS TO BE
 TESTED.
  
 2) THE ENGINEERING SUBMITTED IS NOT ACCEPTABLE. FBC
 1609.1.4 REQUIRES IMPACT RESISTANT COVERINGS TO MEET
 THE REQUIREMENTS OF SSTD 12, ASTM E 1886 AND ASTM E
 1996, OR MIAMI-DADE TAS 201, 202, AND 203. OPENINGS
 LOCATED WITHIN 30 FEET OF GRADE SHALL MEET THE
 REQUIREMENTS OF THE LARGE MISSLE TEST. SUBMIT LARGE
 MISSILE IMPACT TEST REPORTS SPECIFIED FOR THE
 MULLIONS.
  
 3)A RECORDED COPY OF THE NOTICE OF COMMENCEMENT
 MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  