| 2007-11-16 16:45:14 | 1401 BRANYWINE RD |
| | TRAINING FACILITY |
| | 07070433 2ND REV |
| | NOV.16, 2007 |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07070433 |
| | ADD: 1401 BRANYWINE RD |
| | CONT: PURDY CONSTRUCTION |
| | TEL: (561)718-8080 |
| | |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2)THE NOTICE OF COMMENCEMENT SUBMITTED FOR THE TRAINING |
| | CENTER IS OVER 90 DAY OLD, IT WILL NEED TO BE |
| | RE-RECORDED.FL S S 713.13NOTICE OF COMMENCEMENT, TO |
| | BE FILED WITH THE CLERK OF THE COURT.NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| | 713.13(6) THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 3) COMPLIED. |
| | |
| | 4) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE |
| | OF OCCUPANCY: |
| | A) COMPLIED |
| | B) COMPLIED. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, |
| | TABLE 601. AS NOTED ON SHEET A-1, THIS STRUCTURE IS |
| | DESIGNED AS A TYPE II-B BUILDING. THE CITY SHALL REVIEW |
| | THE STRUCTURE AS DECLARED BY THE DESIGN PROFESSIONAL. |
| | THE MINIMUM BUILDING TYPE BY CODE IS A TYPE V-B BY |
| | CODE. |
| | DECLARING THE BUILDING A TYPE II-B THE DESIGNER NEEDS |
| | TO RATE THE ROOFING ASSEMBLY AS STATED IN TABLE 601 |
| | FOOTNOTE ( C ) (2) FIRE RETARDANT TREATED WOOD SHALL BE |
| | USED IN ALL GIRDERS, TRUSSES AND ROOF SHEATHING. |
| | |
| | D-G) COMPLIED. |
| | |
| | 5-12) COMPLIED. |
| | |
| | |
| | |
| | BUILDING PLAN REVIEW II |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |